Evidence map›Paper›PMID 37079597›Full record

ArticlePloS one2023

The effectiveness of post-processing head and neck CT angiography using contrast enhancement boost technique.

Chuluunbaatar Otgonbaatar, Pil-Hyun Jeon, Jae-Kyun Ryu, Hackjoon Shim, Sang-Hyun Jeon, Sung Min Ko, Hyunjung Kim, Jin Woo Kim

Abstract read
In one paragraph

Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Chuluunbaatar OtgonbaatarDepartment of Radiology, College of Medicine, Seoul National University, Seoul, Republic of Korea.ORCID 0000-0002-8533-6165
Pil-Hyun JeonDepartment of Radiology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea.
Jae-Kyun RyuMedical Imaging AI Research Center, Canon Medical Systems Korea, Seoul, Republic of Korea.
Hackjoon ShimMedical Imaging AI Research Center, Canon Medical Systems Korea, Seoul, Republic of Korea.
Sang-Hyun JeonDepartment of Radiology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea.
Sung Min KoDepartment of Radiology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea.
Hyunjung KimDepartment of Radiology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea.ORCID 0000-0001-6522-9883
Jin Woo KimDepartment of Radiology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Republic of Korea.ORCID 0000-0003-3155-0569

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeThis study aimed to investigate the potential of contrast enhancement (CE)-boost technique in the head and neck computed tomography (CT) angiography in terms of the objective and subjective image quality. MATERIALS AND

methodsConsecutive patients who underwent head and neck CT angiography between May 2022 and July 2022 were included. The CE-boost images were generated by combining the subtracted iodinated image and contrast-enhanced image. The objective image analysis was compared for each image with and without CE-boost technique using the CT attenuation, image noise, signal-to-noise-ratio (SNR), contrast-to-noise-ratio (CNR), and image sharpness (full width at half width maximum, FWHM). The subjective image analysis was evaluated by two independent experienced radiologists in the following aspects: the overall image quality, motion artifact, vascular delineation, and vessel sharpness.

resultsA total of 65 patients (mean age, 59.48 ± 13.71 years; range, 24-87 years; 36 women) were included. The CT attenuation of the vertebrobasilar arteries was significantly (p < 0.001) higher in the images obtained using CE-boost technique than in conventional images. Image noise was significantly (p < 0.001) lower for CE-boost images (6.09 ± 1.93) than for conventional images (7.79 ± 1.73). Moreover, CE-boost technique yielded higher SNR (64.43 ± 17.17 vs. 121.37 ± 38.77, p < 0.001) and CNR (56.90 ± 18.79 vs. 116.65 ± 57.44, p < 0.001) than conventional images. CE-boost resulted in shorter FWHM than conventional images (p < 0.001). Higher subjective image quality scores were also demonstrated by the CE-boost than images without CE-boost technique.

conclusionsIn both objective and subjective image analysis, the CE-boost technique provided higher image quality without increasing the flow rate and concentration of contrast media in the head and neck CT angiography. Furthermore, the vessel completeness and delineation were superior in CE-boost images than in conventional images.

Indexed as

Computed Tomography AngiographyContrast MediaAgedAngiographyFemaleHeadHumansMiddle AgedRadiographic Image Interpretation, Computer-AssistedRetrospective StudiesSignal-To-Noise RatioTomography, X-Ray ComputedContrast Media

Identifiers

PMID37079597
PMCPMC10118076

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.