Evidence map›Paper›PMID 37079080›Full record

ArticleMikrochimica acta2023

Electrochemical biomimetic enzyme cascade amplification combined with target-induced DNA walker for detection of thrombin.

Pan Xie, Ding Wang, Hongwen Zhao, Na Yin, Shuang Hu, Wenhan Qin, Li Meng, Xin Pan, Yali Yuan, Ruo Yuan and 1 more

Abstract read
PubMed Publisher
In one paragraph

Article in Mikrochimica acta, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 8 citations in OpenAlex.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 2 institutions in 1 country.

Pan XieDepartment of Nephrology, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, People's Republic of China.
Ding WangKey Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing, 400715, People's Republic of China.
Hongwen ZhaoDepartment of Nephrology, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, People's Republic of China.
Na YinDepartment of Nephrology, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, People's Republic of China.
Shuang HuDepartment of Nephrology, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, People's Republic of China.
Wenhan QinDepartment of Nephrology, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, People's Republic of China.
Li MengDepartment of Nephrology, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, People's Republic of China.
Xin PanDepartment of Nephrology, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, People's Republic of China.
Yali YuanKey Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing, 400715, People's Republic of China.
Ruo YuanKey Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing, 400715, People's Republic of China. yuanruo@swu.edu.cn.ORCID http://orcid.org/0000-0003-3664-6236
Kanfu PengDepartment of Nephrology, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, People's Republic of China. 392906786@qq.com.
Army Medical University · CNSouthwest University · CN

Funding

National Natural Science Foundation of China 22174113National Natural Science Foundation of China 81873606
6 · The paper itself

Abstract

Fe-N-doped carbon nanomaterials (Fe-N/CMs) were designed as a novel biomimetic enzyme with excellent peroxidase-like activity to achieve high-efficient enzyme cascade catalytic amplification with the aid of glucose oxidase (GOx), which was further combined with target-induced DNA walker amplification to develop a sensitive electrochemical biosensor for thrombin detection. Impressively, massive output DNA was transformed from small amounts of target thrombin by highly effective DNA walker amplification as protein-converting strategy, which could then induce the immobilization of functionalized nanozyme on the electrode surface to achieve the high-efficient electrochemical biomimetic enzyme cascade amplification. As a result, an amplified enzyme cascade catalytic signal was measured for thrombin detection ranging from 0.01 pM to 1 nM with a low detection limit of 3 fM. Importantly, the new biomimetic enzyme cascade reaction coupled the advantages of natural enzyme and nanozyme, which paved an avenue to construct varied artificial multienzymes amplification systems for biosensing, bioanalysis, and disease diagnosis applications.

Indexed as

BiomimeticsThrombinDNAElectrochemical TechniquesGlucose OxidaseDNAGlucose OxidaseThrombinAmperometryBiomimetic enzyme cascade reactionElectrochemical biosensorNanozymeSignal amplificationThrombin detection

Identifiers

PMID37079080
OpenAlexW4366463108

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.