Evidence map›Paper›PMID 37077264›Full record

ArticleRSC advances2023

Periodic and quasi-periodic one-dimensional phononic crystal biosensor: a comprehensive study for optimum sensor design.

Abdulkarem H M Almawgani, Hamza Makhlouf Fathy, Hussein A Elsayed, Ghassan Ahmed Ali, Muhammad Irfan, Ahmed Mehaney

Abstract read
In one paragraph

Article in RSC advances, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. A promising ultra-sensitive COScientific reports · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Abdulkarem H M AlmawganiElectrical Engineering Department, College of Engineering, Najran University Najran Kingdom of Saudi Arabia.
Hamza Makhlouf FathyPhysics Department, Faculty of Science, Beni-Suef University Beni-Suef 62512 Egypt ahmed0111236@science.bsu.edu.eg.
Hussein A ElsayedPhysics Department, Faculty of Science, Beni-Suef University Beni-Suef 62512 Egypt ahmed0111236@science.bsu.edu.eg.
Ghassan Ahmed AliInformation Systems Department, College of Computer Sciences and Information Systems, Najran University Najran Saudi Arabia.
Muhammad IrfanElectrical Engineering Department, College of Engineering, Najran University Najran Kingdom of Saudi Arabia.
Ahmed MehaneyPhysics Department, Faculty of Science, Beni-Suef University Beni-Suef 62512 Egypt ahmed0111236@science.bsu.edu.eg.ORCID https://orcid.org/0000-0002-9318-7358

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The resonant acoustic band gap materials have introduced an innovative generation of sensing technology. Based on the local resonant transmitted peaks, this study aims to comprehensively investigate the use of periodic and quasi-periodic one-dimension (1D) layered phononic crystals (PnCs) as a highly sensitive biosensor for the detection and monitoring of sodium iodide (NaI) solution. Meanwhile, a defect layer is introduced defect layer inside the phononic crystal designs to be filled with NaI solution. The proposed biosensor is developed based on the periodic PnCs structure and quasi-periodic PnCs structure. The numerical findings demonstrated that the quasi-periodic PnCs structure provided a wide phononic band gap and a large sensitivity compared to the periodic one. Moreover, many resonance peaks through the transmission spectra are introduced for the quasi-periodic design. The results also show that the resonant peak frequency changes effectively with varying NaI solution concentrations in the third sequence of the quasi-periodic PnCs structure. The sensor can differentiate between concentrations ranging from 0 to 35% with a 5% step, which is extremely satisfying for precise detection and can contribute to a variety of issues in medical applications. Additionally, the sensor provided excellent performance for all the concentrations of the NaI solution. For instance, the sensor has a sensitivity of 959 MHz, a quality factor of 6947, a very low damping factor of 7.19 × 10

Identifiers

PMID37077264
PMCPMC10107728

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.