Evidence map›Paper›PMID 37077256›Full record

ArticleRSC advances2023

Modular 3D-printed fluorometer/photometer for determination of iron(ii), caffeine, and ciprofloxacin in pharmaceutical samples.

Rafaela Silva Lamarca, João Pedro Silva, João Paulo Varoni Dos Santos, Saidy Cristina Ayala-Durán, Paulo Clairmont Feitosa de Lima Gomes

Abstract read
In one paragraph

Article in RSC advances, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Rafaela Silva LamarcaDepartment of Analytical Chemistry, Physical Chemistry and Inorganic Chemistry, National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry, São Paulo State University (UNESP) Araraquara São Paulo 14800-060 Brazil paulo.clairmont@unesp.br.ORCID https://orcid.org/0000-0002-8605-8013
João Pedro SilvaDepartment of Analytical Chemistry, Physical Chemistry and Inorganic Chemistry, National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry, São Paulo State University (UNESP) Araraquara São Paulo 14800-060 Brazil paulo.clairmont@unesp.br.ORCID https://orcid.org/0000-0003-1817-0019
João Paulo Varoni Dos SantosDepartment of Analytical Chemistry, Physical Chemistry and Inorganic Chemistry, National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry, São Paulo State University (UNESP) Araraquara São Paulo 14800-060 Brazil paulo.clairmont@unesp.br.ORCID https://orcid.org/0009-0002-0696-791X
Saidy Cristina Ayala-DuránDepartment of Analytical Chemistry, Physical Chemistry and Inorganic Chemistry, National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry, São Paulo State University (UNESP) Araraquara São Paulo 14800-060 Brazil paulo.clairmont@unesp.br.ORCID https://orcid.org/0000-0001-6311-891X
Paulo Clairmont Feitosa de Lima GomesDepartment of Analytical Chemistry, Physical Chemistry and Inorganic Chemistry, National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Institute of Chemistry, São Paulo State University (UNESP) Araraquara São Paulo 14800-060 Brazil paulo.clairmont@unesp.br.ORCID https://orcid.org/0000-0002-4837-6352

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The demand for the development of portable and low-cost analytical devices has encouraged studies employing additive manufacturing techniques, such as 3D-printing. This method can be used to produce components such as printed electrodes, photometers, and fluorometers for low-cost systems that provide advantages including low sample volume, reduced chemical waste, and easy coupling with LED-based optics and other instrumental devices. In the present work, a modular 3D-printed fluorometer/photometer was designed and applied for the determination of caffeine (CAF), ciprofloxacin (CIP), and Fe(ii) in pharmaceutical samples. All the plastic parts were printed separately by a 3D printer, using Tritan as the plastic material (black color). The final size of the modular 3D-printed device was 12 × 8 cm. The radiation sources were light-emitting diodes (LEDs), while a light dependent resistor (LDR) was used as a photodetector. The analytical curves obtained for the device were: