Evidence map›Paper›PMID 37076840›Full record

ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2023

MRXCAT2.0: Synthesis of realistic numerical phantoms by combining left-ventricular shape learning, biophysical simulations and tissue texture generation.

Stefano Buoso, Thomas Joyce, Nico Schulthess, Sebastian Kozerke

Abstract read
In one paragraph

Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Cardiac neural representations for ECG-guided slice-to-volume reconstruction.Medical & biological engineering & computing · 2026
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Stefano Buoso *Institute for Biomedical Engineering, ETH Zurich and University Zurich, Zurich, Switzerland. buoso@biomed.ee.ethz.ch.ORCID 0000-0002-1293-3225
Thomas Joyce *Institute for Biomedical Engineering, ETH Zurich and University Zurich, Zurich, Switzerland.
Nico SchulthessInstitute for Biomedical Engineering, ETH Zurich and University Zurich, Zurich, Switzerland.
Sebastian KozerkeInstitute for Biomedical Engineering, ETH Zurich and University Zurich, Zurich, Switzerland.

Funding

Swiss National Science Foundation 325230-197702Swiss National Science Foundation CR23I3-166485
6 · The paper itself

Abstract

backgroundStandardised performance assessment of image acquisition, reconstruction and processing methods is limited by the absence of images paired with ground truth reference values. To this end, we propose MRXCAT2.0 to generate synthetic data, covering healthy and pathological function, using a biophysical model. We exemplify the approach by generating cardiovascular magnetic resonance (CMR) images of healthy, infarcted, dilated and hypertrophic left-ventricular (LV) function.

methodIn MRXCAT2.0, the XCAT torso phantom is coupled with a statistical shape model, describing population (patho)physiological variability, and a biophysical model, providing known and detailed functional ground truth of LV morphology and function. CMR balanced steady-state free precession images are generated using MRXCAT2.0 while realistic image appearance is ensured by assigning texturized tissue properties to the phantom labels. FINDING: Paired CMR image and ground truth data of LV function were generated with a range of LV masses (85-140 g), ejection fractions (34-51%) and peak radial and circumferential strains (0.45 to 0.95 and - 0.18 to - 0.13, respectively). These ranges cover healthy and pathological cases, including infarction, dilated and hypertrophic cardiomyopathy. The generation of the anatomy takes a few seconds and it improves on current state-of-the-art models where the pathological representation is not explicitly addressed. For the full simulation framework, the biophysical models require approximately two hours, while image generation requires a few minutes per slice.

conclusionMRXCAT2.0 offers synthesis of realistic images embedding population-based anatomical and functional variability and associated ground truth parameters to facilitate a standardized assessment of CMR acquisition, reconstruction and processing methods.

Indexed as

Magnetic Resonance ImagingVentricular Function, LeftHeartHeart VentriclesHumansMagnetic Resonance Imaging, CinePredictive Value of TestsBiomechanical modelingCardiac magnetic resonanceImage synthesisPopulation variabilityStrain

Identifiers

PMID37076840
PMCPMC10116689

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.