ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2023
The performance of dipole charge density mapping integrated with robotic magnetic navigation in the treatment of atrial tachycardias.
Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 3 citations in OpenAlex.
- Clinical value of robot-assisted catheter navigation for cardiac electrophysiology ablation: current evidence and future directions.Journal of robotic surgery · 2026Review
- Artificial Intelligence in Cardiovascular Imaging and Interventional Cardiology: Emerging Trends and Clinical Implications.Journal of the Society for Cardiovascular Angiography & Interventions · 2025Review
- Charge density mapping in a pediatric patient with symptomatic runs of ectopic atrial tachycardia.HeartRhythm case reports · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCatheter ablation (CA) has become a well-established first-line therapy for a broad spectrum of arrhythmias, including atrial tachycardias (ATs). In this study we aimed to assess the performance of the integrated novel high-resolution new generation noncontact mapping system (AcQMap) with robotic magnetic navigation (RMN) system in CA procedures for patients with ATs including comparing patient subgroups based on the utilized mapping modality, arrhythmia mechanism, localization and type of procedure.
methodsAll patients undergoing CA for AT using the AcQMap-RMN system were included. Procedural safety and efficacy were characterized by intra- and post-procedural complications. Acute procedural success and the long-term outcome were assessed in the overall group and in the subgroups.
resultsA total number of 70 patients were referred for CA with atrial arrhythmias including 67 AT/AFL (mean age 57.1 ± 14.4 years), and 3 additional patients with inappropriate sinus tachycardia. Thirty-eight patients had de novo AT, 24 had post-PVI AT including 2 patients with perinodal AT, and 5 had post-MAZE AT. Two patients (2.9%) suffered post-procedural complications including 1 patient with groin hematoma and 1 patient with a transient ischemic attack. Acute success was achieved in 63/67 (94.0%) procedures. Thirteen patients (19.4%) had documented recurrence at the end of the 12-months follow-up period. The performance of AcQMap was equally good in focal vs. reentry mechanisms (p = 0.61, acute success), in the left and right atrium (p = 0.21).
conclusionsAcQMap-RMN integration might improve success rates in CA of ATs with low number of complications.
Indexed as