Evidence map›Paper›PMID 37074420›Full record

SynthesisSurgical endoscopy2023

Use of High Energy Devices (HEDs) versus electrocautery for laparoscopic cholecystectomy: a systematic review and meta-analysis of randomised controlled trials.

Monica Ortenzi, Ferdinando Agresta, Nereo Vettoretto, Chiara Gerardi, Eleonora Allocati, Emanuele Botteri, Giulia Montori, Andrea Balla, Alberto Arezzo, Giacomo Piatto and 3 more

Open access · hybridAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in Surgical endoscopy, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 2 pooled it
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 2 syntheses or guidelines pooled it, 7 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 8 institutions in 2 countries.

Monica OrtenziDepartment of General and Emergency Surgery, Polytechnic University of Marche, Ancona, Italy. monica.ortenzi@gmail.com.ORCID 0000-0002-6508-6488
Ferdinando AgrestaUnit of General and Emergency Surgery, Vittorio Veneto Hospital, Vittorio Veneto, Treviso, Italy.
Nereo VettorettoGeneral Surgery, ASST Spedali Civili Di Brescia PO Montichiari, Montichiari, Brescia, Italy.
Chiara GerardiIstituto Di Ricerche Farmacologiche Mario Negri IRCCS, Milano, Italy.
Eleonora AllocatiIstituto Di Ricerche Farmacologiche Mario Negri IRCCS, Milano, Italy.
Emanuele BotteriGeneral Surgery, ASST Spedali Civili Di Brescia PO Montichiari, Montichiari, Brescia, Italy.
Giulia MontoriUnit of General and Emergency Surgery, Vittorio Veneto Hospital, Vittorio Veneto, Treviso, Italy.
Andrea BallaGeneral and Minimally Invasive Surgery, Hospital "San Paolo", Civitavecchia, Rome, Italy.
Alberto ArezzoDepartment of Surgical Sciences, University of Torino, Turin, Italy.
Giacomo PiattoDepartment of General Surgery, Ospedale Di Montebelluna, Montebelluna, Treviso, Italy.
Alberto SartoriDepartment of General Surgery, Ospedale Di Montebelluna, Montebelluna, Treviso, Italy.
Stavros AntoniouDepartment of Surgery, Mediterranean Hospital of Cyprus, Limassol, Cyprus.
Mauro PoddaDepartment of Surgical Science, Emergency Surgery Unit, University of Cagliari, Cagliari, Italy.
Azienda Socio Sanitaria Territoriale degli Spedali Civili di Brescia · ITMario Negri Institute for Pharmacological Research · ITOspedale Civile di Vittorio Veneto · ITLimassol General Hospital · CYMarche Polytechnic University · ITOspedale San Paolo · ITUniversity of Cagliari · ITUniversity of Turin · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionAccording to the literature, there is no clear definition of a High Energy Devices (HEDs), and their proper indications for use are also unclear. Nevertheless, the flourishing market of HEDs could make their choice in daily clinical practice arduous, possibly increasing the risk of improper use for a lack of specific training. At the same time, the diffusion of HEDs impacts the economic asset of the healthcare systems. This study aims to assess the efficacy and safety of HEDs compared to electrocautery devices while performing laparoscopic cholecystectomy (LC). MATERIALS AND

methodsOn behalf of the Italian Society of Endoscopic Surgery and New Technologies, experts performed a systematic review and meta-analysis and synthesised the evidence assessing the efficacy and safety of HEDs compared to electrocautery devices while performing laparoscopic cholecystectomy (LC). Only randomised controlled trials (RCTs) and comparative observational studies were included. Outcomes were: operating time, bleeding, intra-operative and post-operative complications, length of hospital stay, costs, and exposition to surgical smoke. The review was registered on PROSPERO (CRD42021250447).

resultsTwenty-six studies were included: 21 RCTs, one prospective parallel arm comparative non-RCT, and one retrospective cohort study, while three were prospective comparative studies. Most of the studies included laparoscopic cholecystectomy performed in an elective setting. All the studies but three analysed the outcomes deriving from the utilisation of US sources of energy compared to electrocautery. Operative time was significantly shorter in the HED group compared to the electrocautery group (15 studies, 1938 patients; SMD - 1.33; 95% CI - 1.89 to 0.78; I2 = 97%, Random-effect). No other statistically significant differences were found in the other examined variables.

conclusionsHEDs seem to have a superiority over Electrocautery while performing LC in terms of operative time, while no difference was observed in terms of length of hospitalisation and blood loss. No concerns about safety were raised.

Indexed as

Cholecystectomy, LaparoscopicLaparoscopyHospitalizationHumansLength of StayPostoperative ComplicationsRandomized Controlled Trials as TopicCholecystectomyHigh Energy DevicesLaparosocpic surgery

Identifiers

PMID37074420
PMCPMC10235147
OpenAlexW4366352910

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked