Trial reportJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists2025
Initial Clinical Experience With AneuFix Injectable Biocompatible Elastomer for Translumbar Embolization of Type 2 Endoleaks.
Trial report in Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02487290 (Feasibility Study of Treatment Type II Endoleaks With ACP-T5), which is not on this map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Feasibility Study of Treatment Type II Endoleaks With ACP-T5: a Novel Approach.
Who cites it
5 citing papers in PubMed, 8 citations in OpenAlex.
- Optimizing the Radiopacity of an Injectable Polymer on Fluoroscopy used for Treatment of Type II Endoleak After Endovascular Aneurysm Repair.Cardiovascular engineering and technology · 2025Article
- A Review of Treatment for Type II Endoleak after Endovascular Abdominal Aortic Aneurysm Repair.Interventional radiology (Higashimatsuyama-shi (Japan) · 2025Review
- Endovascular Repair of Spontaneous Rupture of Stent Graft Branch in Thoracoabdominal Aortic Aneurysm-Management, Case Study, and Review.Journal of clinical medicine · 2024Article
- Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe aim of this study was to assess the initial experience, technical success, and clinical benefit of AneuFix (TripleMed, Geleen, the Netherlands), a novel biocompatible and non-inflammatory elastomer that is directly injected into the aneurysm sac by a translumbar puncture in patients with a type II endoleak and a growing aneurysm. MATERIALS AND
methodsA multicenter, prospective, pivotal study was conducted (ClinicalTrials.gov:NCT02487290). Patients with a type II endoleak and aneurysm growth (>5 mm) were included. Patients with a patent inferior mesenteric artery connected to the endoleak were excluded for initial safety reasons. The endoleak cavity was translumbar punctured with cone-beam computed tomography (CT) and software guidance. Angiography of the endoleak was performed, all lumbar arteries connected to the endoleak were visualized, and AneuFix elastomer was injected into the endoleak cavity and short segment of the lumbar arteries. The primary endpoint was technical success, defined as successful filling of the endoleak cavity with computed tomography angiography (CTA) assessment within 24 hours. Secondary endpoints were clinical success defined as the absence of abdominal aortic aneurysm (AAA) growth at 6 months on CTA, serious adverse events, re-interventions, and neurological abnormalities. Computed tomography angiography follow-up was performed at 1 day and at 3, 6, and 12 months. This analysis reports the initial experience of the first 10 patients treated with AneuFix.
resultsSeven men and 3 women with a median age of 78 years (interquartile range (IQR), 74-84) were treated. Median aneurysm growth after endovascular aneurysm repair (EVAR) was 19 mm (IQR, 8-23 mm). Technical success was 100%; it was possible to puncture the endoleak cavity of all treated patients and to inject AneuFix. Clinical success at 6 months was 90%. One patient showed 5 mm growth with persisting endoleak, probably due to insufficient endoleak filling. No serious adverse events related to the procedure or AneuFix material were reported. No neurological disorders were reported.
conclusionThe first results of type II endoleak treatment with AneuFix injectable elastomer in a small number of patients with a growing aneurysm show that it is technically feasible, safe, and clinically effective at 6 months. CLINICAL IMPACT: Effective and durable embolization of type II endoleaks causing abdominal aortic aneurysms (AAA) growth after EVAR is challenging. A novel injectable elastic polymer (elastomer) was developed, specifically designed to treat type II endoleaks (AneuFix, TripleMed, Geleen, the Netherlands). Embolization of the type II endoleak was performed by translumbar puncture. The viscosity changes from paste-like during injection, into an elastic implant after curing. The initial experience of this multicentre prospective pivotal trial demonstrated that the procedure is feasible and safe with a technical success of 100%. Absence of AAA growth was observed in 9 out of 10 treated patients at 6 months.