Evidence map›Paper›PMID 37073484›Full record

ArticleJournal of applied clinical medical physics2023

Hazard testing to reduce risk in the development of automated planning tools.

Kelly A Nealon, Raphael J Douglas, Eun Young Han, Stephen F Kry, Valerie K Reed, Samantha J Simiele, Laurence E Court

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Kelly A NealonDepartment of Radiation Physics - Research, The University of Texas MD Anderson Cancer Center and The University of Texas MD Anderson Cancer Center UTHealth Houston Graduate School of Biomedical Sciences, Houston, Texas, USA.
Raphael J DouglasDepartment of Radiation Physics - Research, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
Eun Young HanDepartment of Radiation Physics - Patient Care, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
Stephen F KryDepartment of Radiation Physics Outreach, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
Valerie K ReedDepartment of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
Samantha J SimieleDepartment of Radiation Physics - Patient Care, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
Laurence E CourtDepartment of Radiation Physics - Patient Care, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeHazard scenarios were created to assess and reduce the risk of planning errors in automated planning processes. This was accomplished through iterative testing and improvement of examined user interfaces.

methodsAutomated planning requires three user inputs: a computed tomography (CT), a prescription document, known as the service request, and contours. We investigated the ability of users to catch errors that were intentionally introduced into each of these three stages, according to an FMEA analysis. Five radiation therapists each reviewed 15 patient CTs, containing three errors: inappropriate field of view, incorrect superior border, and incorrect identification of isocenter. Four radiation oncology residents reviewed 10 service requests, containing two errors: incorrect prescription and treatment site. Four physicists reviewed 10 contour sets, containing two errors: missing contour slices and inaccurate target contour. Reviewers underwent video training prior to reviewing and providing feedback for various mock plans.

resultsInitially, 75% of hazard scenarios were detected in the service request approval. The visual display of prescription information was then updated to improve the detectability of errors based on user feedback. The change was then validated with five new radiation oncology residents who detected 100% of errors present. 83% of the hazard scenarios were detected in the CT approval portion of the workflow. For the contour approval portion of the workflow none of the errors were detected by physicists, indicating this step will not be used for quality assurance of contours. To mitigate the risk from errors that could occur at this step, radiation oncologists must perform a thorough review of contour quality prior to final plan approval.

conclusionsHazard testing was used to pinpoint the weaknesses of an automated planning tool and as a result, subsequent improvements were made. This study identified that not all workflow steps should be used for quality assurance and demonstrated the importance of performing hazard testing to identify points of risk in automated planning tools.

Indexed as

Radiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedHumansIM/TH- formal quality management tools: general (most aspects)TH- External beam- photons: Development (new technology and techniques)

Identifiers

PMID37073484
PMCPMC10402673

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.