Evidence map›Paper›PMID 37069830›Full record

ArticleMedical physics2023

Quantifying lumen diameter in coronary artery stents with high-resolution photon counting detector CT and convolutional neural network denoising.

Emily K Koons, Jamison E Thorne, Nathan R Huber, Shaojie Chang, Kishore Rajendran, Cynthia H McCollough, Shuai Leng

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
1.9field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Review
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Emily K KoonsDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Jamison E ThorneDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Nathan R HuberDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Shaojie ChangDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Kishore RajendranDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Cynthia H McColloughDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Shuai LengDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Mayo Clinic · USMayo Clinic in Florida · US

Funding

Comprehensive characterization of coronary atherosclerotic disease using photon-counting-detector dual-source CT and its impact on patient managementR01EB028590 · NIBIB · MAYO CLINIC ROCHESTER · PI LENG, SHUAI, MCCOLLOUGH, CYNTHIA H · 2020 to 2023
$2.6M
NIBIB NIH HHS R01 EB028590NIH HHS R01 EB028590
6 · The paper itself

Abstract

backgroundSmall coronary arteries containing stents pose a challenge in CT imaging due to metal-induced blooming artifact. High spatial resolution imaging capability is as the presence of highly attenuating materials limits noninvasive assessment of luminal patency. PURPOSE: The purpose of this study was to quantify the effective lumen diameter within coronary stents using a clinical photon-counting-detector (PCD) CT in concert with a convolutional neural network (CNN) denoising algorithm, compared to an energy-integrating-detector (EID) CT system.

methodsSeven coronary stents of different materials and inner diameters between 3.43 and 4.72 mm were placed in plastic tubes of diameters 3.96-4.87 mm containing 20 mg/mL of iodine solution, mimicking stented contrast-enhanced coronary arteries. Tubes were placed parallel with or perpendicular to the scanner's z-axis in an anthropomorphic phantom emulating an average-sized patient and scanned with a clinical EID-CT and PCD-CT. EID scans were performed using our standard coronary computed tomography angiography (cCTA) protocol (120 kV, 180 quality reference mAs). PCD scans were performed using the ultra-high-resolution (UHR) mode (120 × 0.2 mm collimation) at 120 kV with tube current adjusted so that CTDI

resultsSubstantial blooming artifacts were observed on EID Br40 images, resulting in larger stent struts and reduced lumen diameter (effective diameter underestimated by 41% and 47% for parallel and perpendicular orientations, respectively). Blooming artifacts were observed on EID Br69 images with 19% and 31% underestimation of lumen diameter compared to the caliper for parallel and perpendicular scans, respectively. Overall image quality was substantially improved on PCD, with higher spatial resolution and reduced blooming artifacts, resulting in the clearer delineation of stent struts. Effective lumen diameters were underestimated by 9% and 19% relative to the reference for parallel and perpendicular scans, respectively. CNN reduced image noise by about 50% on PCD images without impacting lumen quantification (<0.3% difference).

conclusionThe PCD UHR mode improved in-stent lumen quantification for all seven stents as compared to EID images due to decreased blooming artifacts. Implementation of CNN denoising algorithms to PCD data substantially improved image quality.

Indexed as

Coronary VesselsTomography, X-Ray ComputedComputed Tomography AngiographyHumansNeural Networks, ComputerPhantoms, ImagingPhotonsStentscomputed tomographyconvolutional neural networkcoronary artery stentsdenoisingphoton counting detector

Identifiers

PMID37069830
PMCPMC10524296
OpenAlexW4366239119

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.