Evidence map›Paper›PMID 37069521›Full record

ArticleBMC musculoskeletal disorders2023

Comparison of three methods for measuring C0-1 angles and C0-2 angles.

Shicai Xu, Fei Ma, Chao Tang, Yehui Liao, Qiang Tang, Shiyu Chen, Qing Wang, Dejun Zhong

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Predictive value of C0-C2 and C1-C2 angles for postoperative lower cervical alignment following posterior atlantoaxial fixation and fusion: a retrospective single-center study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Shicai Xu *Department of Orthopaedics, The Affiliated Hospital of Southwest Medical University, No.25 Taipingjie, Lu Zhou, Sichuan, 646000, PR China.
Fei Ma *Department of Orthopaedics, The Affiliated Hospital of Southwest Medical University, No.25 Taipingjie, Lu Zhou, Sichuan, 646000, PR China.
Chao TangDepartment of Orthopaedics, The Affiliated Hospital of Southwest Medical University, No.25 Taipingjie, Lu Zhou, Sichuan, 646000, PR China.
Yehui LiaoDepartment of Orthopaedics, The Affiliated Hospital of Southwest Medical University, No.25 Taipingjie, Lu Zhou, Sichuan, 646000, PR China.
Qiang TangDepartment of Orthopaedics, The Affiliated Hospital of Southwest Medical University, No.25 Taipingjie, Lu Zhou, Sichuan, 646000, PR China.
Shiyu ChenDepartment of Orthopaedics, The Affiliated Hospital of Southwest Medical University, No.25 Taipingjie, Lu Zhou, Sichuan, 646000, PR China.
Qing WangDepartment of Orthopaedics, The Affiliated Hospital of Southwest Medical University, No.25 Taipingjie, Lu Zhou, Sichuan, 646000, PR China.
Dejun ZhongDepartment of Orthopaedics, The Affiliated Hospital of Southwest Medical University, No.25 Taipingjie, Lu Zhou, Sichuan, 646000, PR China. zdj_1974@163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe mutual compensatory relationship between the upper cervical sagittal alignment and the lower cervical sagittal alignment has been repeatedly reported. However, the evaluation of the upper cervical sagittal parameters are varied in previous studies. This retrospective study was performed to compare three methods for measuring the upper cervical sagittal parameters.

methodsA total of 263 individuals with standing neutral lateral cervical radiographs were included in this study. The Frankfort horizontal line (FHL), foramen magnum line (FML), and McGregor line (ML) were separately used as the reference lines for measuring the C0-1 angle and C0-2 angle. Intraclass correlation (ICC) values were used to compare the consistency and repeatability of the three methods. Pearson's correlation analysis was used to analyze the correlation between the sagittal parameters of the upper and lower cervical spine.

resultsThe interobserver and intraobserver ICC values obtained from using the ML to measure the C0-1 angle and C0-2 angle were both higher than those obtained from using the FML or FHL. The C0-1 angle and C0-2 angle measured by the three methods were negatively correlated with the C2-7 angle. The upper sagittal parameters measured by the FHL were the most correlated with the C2-7 angle. The correlation between the C0-1 angle measured by the three methods and the C0-2 angle measured with the FHL or ML and the C2-7 angle increased with aging.

conclusionUse of the ML to measure the C0-1 angle and C0-2 angle has higher reliability. Use of the FHL to measure the sagittal alignment of the upper cervical spine is more suitable for evaluating the compensation mechanism between the upper and the lower cervical spine.

Indexed as

FluorometholoneLordosisCervical VertebraeHumansNeckReproducibility of ResultsRetrospective StudiesFluorometholoneCervical sagittal parametersCorrelationMeasurementReliability

Identifiers

PMID37069521
PMCPMC10111783

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.