Evidence map›Paper›PMID 37069172›Full record

ArticleScientific reports2023

Feasibility of photon-counting computed tomography as a novel imaging modality for challenging endodontic diagnostic tasks.

Rocharles Cavalcante Fontenele, Fernando Fortes Picoli, Jader Camilo Pinto, Walter Coudyzer, Karla de Faria Vasconcelos, Amanda Farias Gomes, Joke Binst, Reinhilde Jacobs

Abstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Rocharles Cavalcante FonteneleOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, University of Leuven, KU Leuven, Kapucijnenvoer 7, 3000, Leuven, Belgium.
Fernando Fortes PicoliOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, University of Leuven, KU Leuven, Kapucijnenvoer 7, 3000, Leuven, Belgium.
Jader Camilo PintoOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, University of Leuven, KU Leuven, Kapucijnenvoer 7, 3000, Leuven, Belgium.
Walter CoudyzerDepartment of Radiology, UZ Leuven, Leuven, Belgium.
Karla de Faria VasconcelosOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, University of Leuven, KU Leuven, Kapucijnenvoer 7, 3000, Leuven, Belgium.
Amanda Farias GomesDepartment of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil.
Joke BinstDepartment of Radiology, UZ Leuven, Leuven, Belgium.
Reinhilde JacobsOMFS IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, University of Leuven, KU Leuven, Kapucijnenvoer 7, 3000, Leuven, Belgium. reinhilde.jacobs@ki.se.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Photon-counting computed tomography (PCCT) is an innovative technological advancement in relation to x-ray detectors which offers ultra-high-resolution images. The current study aimed to evaluate the visualization ability of PCCT compared to cone-beam computed tomographic (CBCT) devices for challenging endodontic diagnostic tasks. A reference image of an anthropomorphic phantom was acquired using an industrial micro-CT device. Thereafter, the phantom was scanned with three imaging devices, which included PCCT scanner (NAEOTOM Alpha) and two CBCT devices (3D Accuitomo 170 and NewTom VGi evo) having standard and high-resolution acquisition protocols. The diagnostic tasks involved visualizing fine endodontic structures (apical delta, narrow canal, and isthmus) and root cracks. Three experienced examiners assessed the images and were blinded to the PCCT and CBCT devices. Each image was rated according to a three-grade scale (appropriate, acceptable, or inappropriate) for the diagnostic tasks. In relation to fine endodontic structures grouped together, PCCT showed similar diagnostic performance compared to the reference image (p > 0.05). As for the CBCT devices, an excellent performance was only observed with the 3D Accuitomo 170 device at a high-resolution acquisition mode (p > 0.05). The visualization of root cracks was also better with 3D Accuitomo 170 compared to other devices (p < 0.05). Overall, PCCT and 3D Accuitomo 170 at a high-resolution setting showed similar performance for visualizing fine endodontic structures. In addition, the high-resolution CBCT protocol was superior for visualizing root cracks compared to both PCCT and other standard- and high-resolution CBCT protocols.

Indexed as

Cone-Beam Computed TomographyFeasibility StudiesPhantoms, ImagingX-Ray Microtomography

Identifiers

PMID37069172
PMCPMC10110619

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked