Evidence map›Paper›PMID 37068476›Full record

ArticleBlood purification2023

Increased Longevity of a Novel Gas Exchanger System for Low-Flow Veno-Venous Extracorporeal CO2 Removal in Acute Hypercapnic Respiratory Failure.

Shalimar Mila Konopasek, Stephanie Klinzing, Pedro David Wendel Garcia, Matthias Peter Hilty, Marco Maggiorini

Open access · hybridAbstract read
In one paragraph

Article in Blood purification, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 63% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Shalimar Mila KonopasekInstitute of Intensive Care Medicine, University Hospital of Zurich, Zurich, Switzerland.
Stephanie KlinzingInstitute of Intensive Care Medicine, University Hospital of Zurich, Zurich, Switzerland.
Pedro David Wendel GarciaInstitute of Intensive Care Medicine, University Hospital of Zurich, Zurich, Switzerland.
Matthias Peter HiltyInstitute of Intensive Care Medicine, University Hospital of Zurich, Zurich, Switzerland.
Marco MaggioriniInstitute of Intensive Care Medicine, University Hospital of Zurich, Zurich, Switzerland.
University Hospital of Zurich · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionLow-flow veno-venous extracorporeal CO2 removal (ECCO2R) is an adjunctive therapy to support lung protective ventilation or maintain spontaneous breathing in hypercapnic respiratory failure. Low-flow ECCO2R is less invasive compared to higher flow systems, while potentially compromising efficiency and membrane lifetime. To counteract this shortcoming, a high-longevity system has recently been developed. Our hypotheses were that the novel membrane system provides runtimes up to 120 h, and CO2 removal remains constant throughout membrane system lifetime.

methodsSeventy patients with pH ≤ 7.25 and/or PaCO2 ≥9 kPa exceeding lung protective ventilation limits, or experiencing respiratory exhaustion during spontaneous breathing, were treated with the high-longevity ProLUNG system or in a control group using the original gas exchanger. Treatment parameters, gas exchanger runtime, and sweep-gas VCO2 were recorded across 9,806 treatment-hours and retrospectively analyzed.

results25/33 and 23/37 patients were mechanically ventilated as opposed to awake spontaneously breathing in both groups. The high-longevity system increased gas exchanger runtime from 29 ± 16 to 48 ± 36 h in ventilated and from 22 ± 14 to 31 ± 31 h in awake patients (p < 0.0001), with longer runtime in the former (p < 0.01). VCO2 remained constant at 86 ± 34 mL/min (p = 0.11). Overall, PaCO2 decreased from 9.1 ± 2.0 to 7.9 ± 1.9 kPa within 1 h (p < 0.001). Tidal volume could be maintained at 5.4 ± 1.8 versus 5.7 ± 2.2 mL/kg at 120 h (p = 0.60), and peak airway pressure could be reduced from 31.1 ± 5.1 to 27.5 ± 6.8 mbar (p < 0.01).

conclusionUsing a high-longevity gas exchanger system, membrane lifetime in low-flow ECCO2R could be extended in comparison to previous systems but remained below 120 h, especially in spontaneously breathing patients. Extracorporeal VCO2 remained constant throughout gas exchanger system runtime and was consistent with removal of approximately 50% of expected CO2 production, enabling lung protective ventilation despite hypercapnic respiratory failure.

Indexed as

Respiratory Distress SyndromeRespiratory InsufficiencyCarbon DioxideHumansRespiration, ArtificialRetrospective StudiesCarbon DioxideAcute respiratory distress syndromeChronic obstructive pulmonary diseaseExtracorporeal circulationExtracorporeal CO2 removalLung protective ventilationRespiratory acidosisRespiratory failure

Identifiers

PMID37068476
PMCPMC10129028
OpenAlexW4308135999

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.