Evidence map›Paper›PMID 37067193›Full record

Trial reportEuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology2023

Feasibility of redo-TAVI in self-expanding Evolut valves: a CT analysis from the Evolut Low Risk Trial substudy.

Kendra J Grubb, Nikoloz Shekiladze, Julianne Spencer, Emily Perdoncin, Gilbert H L Tang, Joe Xie, John Lisko, Jorge Zhingre Sanchez, Lindsay M Lucas, Janarthanan Sathananthan and 8 more

Registry-linked trialAbstract readClinical Trial
In one paragraph

Trial report in EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02701283 (Transcatheter Aortic Valve Replacement With the Medtronic Transcatheter Aortic Valve Replacement System In Patients at Low Risk for Surgical Aortic Valve Replacement), which is not on this map. Cited by 25 papers.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02701283 naactive not recruitingnot on this map

Transcatheter Aortic Valve Replacement With the Medtronic Transcatheter Aortic Valve Replacement System In Patients at Low Risk for Surgical Aortic Valve Replacement

TypeinterventionalSponsorMedtronic CardiovascularRan2016 to 2029Enrolled2,223ConditionsAortic Valve StenosisArmsMedtronic Transcatheter Aortic Valve Replacement Systems, Surgical Aortic Valve Replacement (SAVR)
3 · Its place in the literature

Who cites it

25 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Review
  6. TAVI-in-TAVI in a patient with morquio syndrome: a case report.European heart journal. Case reports · 2026
    Article
  7. Article
  8. Article
  9. Review
  10. Chimney stenting for preventing coronary obstruction in redo-TAVI with balloon-expandable valves within self-expanding valves.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2025
    Article
  11. Review
  12. Article
  13. Review
  14. Lifetime management considerations to optimise transcatheter aortic valve implantation: a practical guide.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2024
    Review
  15. Redo-TAVI with the SAPIEN 3 valve in degenerated calcified CoreValve/Evolut explants.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2024
    Article
  16. Feasibility of redo-TAVI in the self-expanding ACURATE neo2 valve: a computed tomography study.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2024
    Article
  17. Redo-TAVI feasibility and coronary accessibility following index TAVI with the Evolut valve in patients with bicuspid aortic valve stenosis.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2024
    Article
  18. Article
  19. Article
  20. Splitter - a novel device for leaflet modification in transcatheter aortic valve-in-valve implantation procedures.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

18 authors.

Kendra J GrubbDivision of Cardiothoracic Surgery, Emory University, Atlanta, GA, USA.
Nikoloz ShekiladzeDivision of Cardiothoracic Surgery, Emory University, Atlanta, GA, USA.
Julianne SpencerResearch and Development, Structural Heart & Aortic, Medtronic, Mounds View, MN, USA.
Emily PerdoncinDivision of Cardiothoracic Surgery, Emory University, Atlanta, GA, USA.
Gilbert H L TangDepartment of Cardiovascular Surgery, Mount Sinai Health System, New York, NY, USA.
Joe XieDivision of Cardiothoracic Surgery, Emory University, Atlanta, GA, USA.
John LiskoDivision of Cardiothoracic Surgery, Emory University, Atlanta, GA, USA.
Jorge Zhingre SanchezResearch and Development, Structural Heart & Aortic, Medtronic, Mounds View, MN, USA.
Lindsay M LucasNAMSA, Minneapolis, MN, USA.
Janarthanan SathananthanCentre for Heart Valve Innovation, St. Paul's Hospital, University of British Columbia, Vancouver, BC, Canada.
Toby RogersSection of Interventional Cardiology, MedStar Washington Hospital Center, Washington, D.C., USA.
G Michael DeebDepartment of Cardiac Surgery, University of Michigan Hospital, Ann Arbor, MI, USA.
Shinichi FukuharaDepartment of Cardiac Surgery, University of Michigan Hospital, Ann Arbor, MI, USA.
Philipp BlankeCentre for Heart Valve Innovation, St. Paul's Hospital, University of British Columbia, Vancouver, BC, Canada.
Jonathon A LeipsicCentre for Heart Valve Innovation, St. Paul's Hospital, University of British Columbia, Vancouver, BC, Canada.
John K ForrestSection of Cardiology, Yale School of Medicine, New Haven, CT, USA.
Michael J ReardonDepartment of Cardiovascular Surgery, Houston Methodist, Houston, TX, USA.
Patrick GleasonStructural Heart and Valve Center, Emory University, Atlanta, GA, USA.

Funding

Yale Clinical and Translational Science Award (U Component)UL1TR001863 · NCATS · YALE UNIVERSITY · PI John H. Krystal, LUCILA OHNO-MACHADO · 2016 to 2026
$102.9M
NCATS NIH HHS UL1 TR001863
6 · The paper itself

Abstract

backgroundTranscatheter aortic valve implantation in an existing transcatheter valve (redo-TAVI) pins the index valve leaflets in the open position (neoskirt), which can cause coronary flow compromise and limit access. Whether anatomy may preclude redo-TAVI in self-expanding Evolut valves is unknown.

aimsWe aimed to evaluate the anatomical feasibility of redo-TAVI by simulating implantation of a balloon-expandable SAPIEN 3 (S3) within an Evolut or an Evolut within an Evolut.

methodsA total of 204 post-TAVI computed tomography (CT) scans from the Evolut Low Risk CT substudy were analysed. Five redo-TAVI positions were evaluated: S3-in-Evolut inflow-to-inflow, S3 outflow at Evolut nodes 4, 5, and 6, and Evolut-in-Evolut inflow-to-inflow. Univariable modelling identified pre-TAVI clinical characteristics, CT anatomical parameters, and procedural variables associated with coronary flow compromise using the neoskirt height and post-TAVI aortic root dimensions.

resultsThe risk of coronary flow compromise was lowest when the S3 outflow was at Evolut node 4 (20%) and highest when at Evolut node 6 (75%). The highest likelihood of preserving coronary accessibility occurred with the S3 outflow at Evolut node 4. Female sex and higher body mass index were associated with a higher risk of coronary flow compromise, as were a smaller annulus diameter, lower sinus of Valsalva height and width, shorter coronary height, smaller sinotubular junction diameter, and shallower Evolut implant depth.

conclusionsThe feasibility of redo-TAVI after Evolut failure is multifactorial and relates to the native annular anatomy, as well as the implantation depth of the index and second bioprostheses. Placement of an S3 at a lower Evolut position may reduce the risk of coronary flow compromise while preserving coronary access. CLINICALTRIALS: gov: NCT02701283.

Indexed as

Aortic Valve StenosisHeart Valve ProsthesisTranscatheter Aortic Valve ReplacementAortic ValveFeasibility StudiesFemaleHumansProsthesis DesignTomography, X-Ray ComputedTreatment Outcome

Identifiers

PMID37067193
PMCPMC10333920

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.