ArticleRadiation physics and chemistry (Oxford, England : 1993)2023
Effectiveness of protective thyroid shield in chest X-ray imaging.
Article in Radiation physics and chemistry (Oxford, England : 1993), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 5 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Chest X-ray imaging is the most common X-ray imaging method for diagnosing coronavirus disease. The thyroid gland is one of the most radiation-sensitive organs of the body, particularly in infants and children. Therefore, it must be protected during chest X-ray imaging. Yet, because it has benefits and drawbacks, using a thyroid shield as protection during chest X-ray imaging is still up for debate.Therefore, this study aims to clarify the need for using a protective thyroid shield during chest X-ray imaging. This study was performed using different dosimeters (silica beads as a thermoluminescent dosimeter and an optically stimulated luminance dosimeter) embedded in an adult male ATOM dosimetric phantom. The phantom was irradiated using a portable X-ray machine with and without thyroid shielding. The dosimeter readings indicated that a thyroid shield reduced the radiation dose to the thyroid gland by 69% ± 18% without degrading the obtained radiograph. The use of a protective thyroid shield during chest X-ray imaging is recommended because its benefits outweigh the risks.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.