Evidence map›Paper›PMID 37064446›Full record

ArticleHeliyon2023

Safety evaluation of the Guardian device on the common carotid artery in sheep.

Natalie L James, Zoran Milijasevic, Anthony Ujhazy, David Huber, Randi Rotne, Glenn Edwards, Kieri Jermyn, David S Celermajer

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 96% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Natalie L JamesThe Brain Protection Company, 'F3 the Entertainment Quarter' Suite 210, 122 Lang Road, Moore Park, NSW 2021, Australia.
Zoran MilijasevicThe Brain Protection Company, 'F3 the Entertainment Quarter' Suite 210, 122 Lang Road, Moore Park, NSW 2021, Australia.
Anthony UjhazyThe Brain Protection Company, 'F3 the Entertainment Quarter' Suite 210, 122 Lang Road, Moore Park, NSW 2021, Australia.
David HuberWollongong Private Hospital, 3/363 Crown Street, Wollongong, NSW 2500, Australia.
Randi RotneSchool of Agricultural, Environmental and Veterinary Services, Charles Sturt University, Wagga Wagga, NSW 2650, Australia.
Glenn EdwardsSchool of Agricultural, Environmental and Veterinary Services, Charles Sturt University, Wagga Wagga, NSW 2650, Australia.
Kieri JermynSchool of Agricultural, Environmental and Veterinary Services, Charles Sturt University, Wagga Wagga, NSW 2650, Australia.
David S CelermajerThe Brain Protection Company, 'F3 the Entertainment Quarter' Suite 210, 122 Lang Road, Moore Park, NSW 2021, Australia.
Charles Sturt University · AUWollongong Hospital · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Pulse pressure intensity in middle-aged adults is a risk factor for dementia. The Guardian device (The Brain Protection Company, Sydney, Australia) has been developed to reduce pulse pressure, as a potential therapy. Objectives: The aim of this study was to evaluate the safety of the Guardian, a novel pulse modulation device designed to reduce the intensity of the pulse pressure that penetrates into the cerebral small vessels. The Guardian is a helix that gently wraps around the common carotid artery (CCA) to slightly change its shape, to absorb pulsatility, without lowering flow. Methods: The Guardian was implanted bilaterally on the CCAs of 10 mature sheep for chronic implant periods of 3, 6 or 8 months. The ratio of internal device diameter to outer diameter of the CCA varied from 63% to 92% (n = 20). The implant position on the vessel was marked surgically at implant. Gross pathology and histopathology of the CCA were examined at 3- and 6-months post explant. Most devices were explanted using open surgery, however minimally invasive surgical explant techniques were examined in 2 animals to assess the potential of this approach for explant in humans if required. Results: The Guardian was successfully implanted with no adverse events, and minimally invasive explant appeared to be viable for removal. Following implant, the device was surrounded by a thin fibrous capsule, with similar pathology at 3- and 6-months. Minimal or no movement was observed. CCA sections appeared histologically normal, with no evidence of thrombosis, stenosis, fibrosis, chronic inflammatory response, or vessel degeneration. Conclusions: The feasibility of surgical implantation and biomaterial safety of the Guardian was confirmed over 8 months. Minimally invasive explant of the Guardian has the potential to be viable. Further work is required to demonstrate efficacy

Indexed as

Alzheimer's dementiaChronic implantCommon carotid arteryDementiaPulse pressure waveSheep

Identifiers

PMID37064446
PMCPMC10102196
OpenAlexW4360981304

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.