Evidence map›Paper›PMID 37064386›Full record

ArticleQuantitative imaging in medicine and surgery2023

Image quality evaluation of diffusion-weighted imaging in bladder cancer: a comparison between integrated slice-specific dynamic shimming and single-shot echo-planar imaging.

Yiqian Wang, Shaobin Chen, Wei Zhang, Weixiong Xiao, Jiawei Su, Ruochen Zhang, Yongbao Wei, Min Luo

Open access · diamondAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Yiqian Wang *Shengli Clinical Medical College of Fujian Medical University, Fuzhou, China.
Shaobin Chen *Shengli Clinical Medical College of Fujian Medical University, Fuzhou, China.
Wei ZhangShengli Clinical Medical College of Fujian Medical University, Fuzhou, China.
Weixiong XiaoShengli Clinical Medical College of Fujian Medical University, Fuzhou, China.
Jiawei SuShengli Clinical Medical College of Fujian Medical University, Fuzhou, China.
Ruochen ZhangShengli Clinical Medical College of Fujian Medical University, Fuzhou, China.
Yongbao WeiShengli Clinical Medical College of Fujian Medical University, Fuzhou, China.
Min LuoShengli Clinical Medical College of Fujian Medical University, Fuzhou, China.
Fujian Provincial Hospital · CNFujian Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Diffusion-weighted imaging (DWI) image quality will affect how well radiologists detect lesions and judge muscular invasion. This study qualitatively and quantitatively compared the image quality of DWI with integrated slice-specific dynamic shimming (iShim) and single-shot echo-planar imaging (SS-EPI) in the diagnosis of bladder cancer (BC) using 3.0 T magnetic resonance imaging (MRI). We also investigated the application value of iShim DWI in BC. Methods: This retrospective study enrolled 97 patients with BC who underwent a preoperative MRI examination, including iShim and SS-EPI DWI. Two radiologists, blinded to the type of DWI, independently rated DWIs on a 5-point Likert scale regarding image quality features (anatomical details, distortion, lesion conspicuity, artifacts, and overall image quality) and evaluated tumor muscular invasion. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), apparent diffusion coefficient (ADC) values, and tumor numbers were manually recorded by another 2 radiologists. Pathologists recorded tumor numbers and sizes in a standard manner. Results: The inter- and intraobserver consistency of image quality features scoring was good to excellent (κ >0.75; P<0.001). The scores of iShim DWI were higher than those of SS-EPI DWI in terms of distortion, artifacts, and overall image quality (P<0.001). The SNR and CNR of iShim DWI were higher than those of SS-EPI DWI (P<0.001), but there was no significant difference in ADC values between the 2 sequences (P>0.05). Based on pathological findings, the sensitivity of iShim and SS-EPI DWI in diagnosing tumor that diameter less than 1 cm was 100% (79/79) and 93.7% (74/79), respectively. The specificity and accuracy (95.2% and 90.2%, respectively) of iShim DWI in diagnosing tumor muscular invasion were significantly higher than those of SS-EPI DWI (76.2% and 80.4%, respectively). The area under the receiver operating characteristic curve of iShim DWI was significantly higher than that of SS-EPI DWI in diagnosing tumor muscular invasion (P=0.017). Conclusions: Compared with SS-EPI DWI, iShim DWI provided higher image quality. iShim DWI effectively detected BC and better identified muscular invasion. This finding can guide the clinical selection of appropriate treatments for patients with BC.

Indexed as

Bladder cancer (BC)diffusion-weighted imaging (DWI)image qualityintegrated slice-specific dynamic shimming (iShim)magnetic resonance imaging (MRI)

Identifiers

PMID37064386
PMCPMC10102749
OpenAlexW4321351040

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.