ArticleQuantitative imaging in medicine and surgery2023
Automatic prediction model for online diaphragm motion tracking based on optical surface monitoring by machine learning.
Article in Quantitative imaging in medicine and surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- A study on indirect tumor localization using lung phantom during radiation therapy.Quantitative imaging in medicine and surgery · 2025Article
- Data-Driven Volumetric Computed Tomography Image Generation From Surface Structures Using a Patient-Specific Deep Leaning Model.International journal of radiation oncology, biology, physics · 2025Article
- Artificial intelligence-based motion tracking in cancer radiotherapy: A review.Journal of applied clinical medical physics · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: The aim of this study was to establish a correlation model between external surface motion and internal diaphragm apex movement using machine learning and to realize online automatic prediction of the diaphragm motion trajectory based on optical surface monitoring. Methods: The optical body surface parameters and kilovoltage (kV) X-ray fluoroscopic images of 7 liver tumor patients were captured synchronously for 50 seconds. The location of the diaphragm apex was manually delineated by a radiation oncologist and automatically detected with a convolutional network model in fluoroscopic images. The correlation model between the body surface parameters and the diaphragm apex of each patient was developed through linear regression (LR) based on synchronous datasets before radiotherapy. Model 1 (M1) was trained with data from the first 30 seconds of the datasets and tested with data from the following 20 seconds of the datasets in the first fraction to evaluate the intra-fractional prediction accuracy. Model 2 (M2) was trained with data from the first 30 seconds of the datasets in the next fraction. The motion trajectory of the diaphragm apex during the following 20 seconds in the next fraction was predicted with M1 and M2, respectively, to evaluate the inter-fractional prediction accuracy. The prediction errors of the 2 models were compared to analyze whether the correlation model needed to be re-established. Results: The average mean absolute error (MAE) and root mean square error (RMSE) using M1 trained with automatic detection location for the first fraction were 3.12±0.80 and 3.82±0.98 mm in the superior-inferior (SI) direction and 1.38±0.24 and 1.74±0.32 mm in the anterior-posterior (AP) direction, respectively. The average MAE and RMSE of M1 versus M2 in the AP direction were 2.63±0.71 versus 1.28±0.48 mm and 3.26±0.90 versus 1.61±0.60 mm, respectively. The average MAE and RMSE of M1 versus M2 in the SI direction were 5.84±1.22 versus 3.37±0.43 mm and 7.22±1.45 versus 4.07±0.54 mm, respectively. The prediction accuracy of M2 was significantly higher than that of M1. Conclusions: This study shows that it is feasible to use optical body surface information to automatically predict the diaphragm motion trajectory. At the same time, it is necessary to establish a new correlation model for the current fraction before each treatment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.