Evidence map›Paper›PMID 37063930›Full record

ArticleMedical research archives2023

Development of a Solvability Map.

Gengsheng L Zeng

Abstract read
In one paragraph

Article in Medical research archives, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Gengsheng L ZengDepartment Computer Science, Utah Valley University, Orem, UT 84058, USA.

Funding

Reducing Metal Artifacts in Clinical X-Ray CT via Image Reconstruction TechniquesR15EB024283 · NIBIB · WEBER STATE UNIVERSITY · PI ZENG, GENGSHENG · 2018 to 2022
$644k
NIBIB NIH HHS R15 EB024283
6 · The paper itself

Abstract

From time to time, it is necessary to determine whether there are sufficient measurements for the image reconstruction task especially when a non-standard scanning geometry is used. When the imaging system can be approximately modeled as a system of linear equations, the condition number of the system matrix indicates whether the entire system can be stably solved as a whole. When the system as a whole cannot be stably solved, the Moore-Penrose pseudo inverse matrix can be evaluated through the singular value decomposition (SVD) and then a generalized solution can be obtained. However, these methods are not practical because they require the computer memory to store the whole system matrix, which is often too large to store. Also, we do not know if the generalized solution is good enough for the application in mind. This paper proposes a practical image solvability map, which can be obtained for any practical image reconstruction algorithm. This image solvability map measures the reconstruction errors for each location using a large number of computer-simulated random phantoms. In other words, the map is generated by a Monte Carlo approach.

Indexed as

Biomedical imagingComputed TomographyComputer simulationsImage reconstructionInternal problemInverse problemMonte Carlo

Identifiers

PMID37063930
PMCPMC10100585

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.