Evidence map›Paper›PMID 37063762›Full record

ArticleResearch and practice in thrombosis and haemostasis2023

Elevated thrombin generation levels in the left atrial appendage in patients with atrial fibrillation.

Adi Elias, Yara Khoury, Faheem Shehadeh, Gilat Ron, Monther Boulos, Jeries Nashashibi, Robert Zukermann, Mazen Elias, Lior Gepstein, Mahmoud Suleiman

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in Research and practice in thrombosis and haemostasis, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03795883 (The Thrombotic Potential), which is not on this map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03795883 completednot on this map

The Thrombotic Potential (Thrombin Generation) of Left Atrium and Other Heart Chambers in Atrial Fibrillation Patients Compared to Patients Without Atrial Fibrillation.

TypeobservationalSponsorRambam Health Care CampusRan2019 to 2022Enrolled47ConditionsAtrial Fibrillation, Thrombosis Cardiac, Left Atrial Thrombosis
3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Adi EliasDepartment of Cardiology, Rambam Health Care Campus, Haifa, Israel.
Yara KhouryDepartment of Internal Medicine H, Rambam Health Care Campus, Haifa, Israel.
Faheem ShehadehDivision of Pacing and Electrophysiology, Rambam Health Care Campus, Haifa, Israel.
Gilat RonDepartment of Internal Medicine C, Emek Medical Center, Afula, Israel.
Monther BoulosDivision of Pacing and Electrophysiology, Rambam Health Care Campus, Haifa, Israel.
Jeries NashashibiDepartment of Cardiology, Rambam Health Care Campus, Haifa, Israel.
Robert ZukermannDepartment of Cardiology, Rambam Health Care Campus, Haifa, Israel.
Mazen EliasDepartment of Internal Medicine C, Emek Medical Center, Afula, Israel.
Lior GepsteinDivision of Pacing and Electrophysiology, Rambam Health Care Campus, Haifa, Israel.
Mahmoud SuleimanDivision of Pacing and Electrophysiology, Rambam Health Care Campus, Haifa, Israel.
Rambam Health Care Campus · ILEmek Medical Center · IL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Atrial Fibrillation (AF) is the most common sustained tachi-arrhythmia. Thrombus formation in the left atrial appendage (LAA) increases the risk of stroke and systemic embolism in patients with AF. Objectives: The aim of this study was to compare thrombin generation in the LAA to the LA among patients with AF. Methods: A cross-sectional study of consecutive patients with AF undergoing pulmonary veins catheter ablation. Blood samples from the femoral vein (FV), right atrium (RA), left atrium (LA), and LAA were collected during the catheter ablation procedures. Thrombin generation was assessed by a Calibrated Automated Thrombogram. The LAA-calibrated automated thrombogram parameters were compared with the RA, LA, and FV. Results: A total of 47 consecutive patients were enrolled in the study. The endogenous thrombin potential and peak height were significantly higher in the LAA compared with the LA, the mean differences and 95% CI between the LA and LAA were -378.9 (-680.5, -77.2) (nM∗min) and -66.7 (-119.6, -13.8) (nM) in the endogenous thrombin potential and peak height respectively. Conclusion: In patients with AF undergoing catheter ablation, the LAA demonstrated increased thrombin generation compared with the LA. This finding might contribute to the understanding of why the LAA is more predisposed to thrombus formation than the LA. Clinical Trials Registration: NCT03795883.

Indexed as

atrial fibrillationcatheter ablationleft atrial appendagethrombinthrombus

Identifiers

PMID37063762
PMCPMC10099305
OpenAlexW4324339971

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.