Evidence map›Paper›PMID 37063492›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2023

PKAID-Net: Prior Knowledge Aware Iterative Denoising Neural Network for Photon Counting Detector CT.

Shaojie Chang, Jeffrey F Marsh, Emily K Koons, Hao Gong, Cynthia H McCollough, Shuai Leng

Open access · greenAbstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Improving Stenosis Assessment in Energy Integrating Detector CT via Learned Monoenergetic Imaging Capability.Proceedings of SPIE--the International Society for Optical Engineering · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Shaojie ChangDepartment of Radiology, Mayo Clinic, Rochester, MN, 55901, USA.
Jeffrey F MarshDepartment of Radiology, Mayo Clinic, Rochester, MN, 55901, USA.
Emily K KoonsDepartment of Radiology, Mayo Clinic, Rochester, MN, 55901, USA.
Hao GongDepartment of Radiology, Mayo Clinic, Rochester, MN, 55901, USA.
Cynthia H McColloughDepartment of Radiology, Mayo Clinic, Rochester, MN, 55901, USA.
Shuai LengDepartment of Radiology, Mayo Clinic, Rochester, MN, 55901, USA.
WinnMed · US

Funding

Comprehensive characterization of coronary atherosclerotic disease using photon-counting-detector dual-source CT and its impact on patient managementR01EB028590 · NIBIB · MAYO CLINIC ROCHESTER · PI LENG, SHUAI, MCCOLLOUGH, CYNTHIA H · 2020 to 2023
$2.6M
NIBIB NIH HHS R01 EB028590
6 · The paper itself

Abstract

An important feature enabled by Photon-Counting Detector (PCD) CT is the simultaneous acquisition of multi-energy data, which can produce virtual monoenergetic images (VMIs) at a high spatial resolution. However, noise levels observed in the high-resolution (HR) VMIs are markedly increased. Recent work involving deep learning methods has shown great potential in CT image denoising. Many CNN applications involve training using spatially co-registered low- and high-dose CT images featuring high and low image noise, respectively. However, this is implausible in routine clinical practice. Further, typical denoising methods treat each VMI energy level independently, without consideration of the valuable information in the spectral domain. To overcome these obstacles, we propose a prior knowledge-aware iterative denoising neural network (PKAID-Net). PKAID-Net offers two major benefits: first, it utilizes spectral information by including a lower-noise VMI as a prior input; and second, it iteratively constructs refined datasets for neural network training to improve the denoising performance. This study includes 10 patient coronary CT angiography (CTA) exams acquired on a clinical HR PCD-CT (NAEOTOM Alpha, Siemens Healthineers). The HR VMIs were reconstructed at 50 and 70 keV, using a sharp kernel (Bv68) and thin (0.6 mm, 0.3 mm increment) slice thickness. Results showed that the PKAID-Net provided a noise reduction of 96% and 70% relative to FBP and iterative reconstruction, respectively while maintaining spatial and spectral fidelity and a natural noise texture. These results demonstrate the noise reduction capacity of PKAID-Net as applied to cutting-edge PCD-CT data to enable HR, multi-energy cardiac CT imaging.

Indexed as

coronary computed tomography angiographyDeep learninghigh resolutionnoise reductionphoton counting detector CTprior information

Identifiers

PMID37063492
PMCPMC10099786
OpenAlexW4362693441

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked