Evidence map›Paper›PMID 37059976›Full record

ArticleBMC musculoskeletal disorders2023

Biomechanical effects of internal fixation with self-lock compression anti-rotation blade for Pauwels type III femoral neck fractures: a comparative finite element analysis.

Bo-Xuan Huang, Si-Zheng Zhan, Ming Yang, Dian-Ying Zhang

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. [Comparison of effectiveness of three surgical methods in treatment of Pauwels typeZhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Bo-Xuan HuangDepartment of Orthopedics and Trauma, Peking University People's Hospital, No. 11 Xizhimen South Street, Xicheng District, Beijing, 100044, China.
Si-Zheng ZhanDepartment of Orthopedics and Trauma, Peking University People's Hospital, No. 11 Xizhimen South Street, Xicheng District, Beijing, 100044, China.
Ming YangDepartment of Orthopedics and Trauma, Peking University People's Hospital, No. 11 Xizhimen South Street, Xicheng District, Beijing, 100044, China. pku_ym@163.com.
Dian-Ying ZhangDepartment of Orthopedics and Trauma, Peking University People's Hospital, No. 11 Xizhimen South Street, Xicheng District, Beijing, 100044, China.
Peking University · CNPeking University People's Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSelf-lock compression anti-rotation blade (SCAB) is a novel internal fixation implant for femoral neck fractures (FNF). We conducted this finite element analysis study to evaluate the biomechanical performances of SCAB combined with a cannulated screw for fixation of Pauwels type III FNF.

methodsThree finite element models of Pauwels type III FNF treated with various internal fixations were established: a: the inverted triangular parallel cannulated screw (3CS) model, b: the biplane double-supported screw fixation (BDSF) model, c: the SCAB combined with a cannulated screw model. Displacement and Von Mises stress of femurs and internal fixations under increasing loads as well as the average stress on fracture surfaces and maximum displacements on the X and Z axis of proximal fracture fragments at maximum load were measured and compared.

resultThe SCAB-based internal fixation exhibited superior biomechanical performances compared with 3CS and BDSF configurations, as the former resulted in lower parameters including displacement of the femur, Von Mises stress of internal fixation, stress on fracture surfaces as well as X and Z axis displacement of fracture fragments.

conclusionInternal fixation using SCAB combined with a cannulated screw for Pauwels type III FNFs shows enough stability, with satisfied resistance to varus and shearing forces, which may provide a new option for the treatment of FNFs.

Indexed as

Femoral Neck FracturesBiomechanical PhenomenaBone ScrewsFemurFinite Element AnalysisFracture Fixation, InternalHumansCannulated screwFemoral neck fractureFinite element analysisInternal fixationPauwels type IIISelf-lock compression anti-rotation blade

Identifiers

PMID37059976
PMCPMC10103490
OpenAlexW4365515407

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.