Evidence map›Paper›PMID 37059748›Full record

ArticleScientific reports2023

Fluid-structure interaction modelling of a positive-displacement Total Artificial Heart.

Joseph Bornoff, Azad Najar, Libera Fresiello, Thomas Finocchiaro, Ina Laura Perkins, Harinderjit Gill, Andrew N Cookson, Katharine H Fraser

Abstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review
  3. Novel para-aortic cardiac assistance using a pre-stretched dielectric elastomer actuator.Interdisciplinary cardiovascular and thoracic surgery · 2024
    Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Joseph BornoffDepartment of Mechanical Engineering, University of Bath, Bath, UK.
Azad NajarScandinavian Real Heart AB, Västerås, Sweden.
Libera FresielloFaculty of Science and Technology, University of Twente, Twente, The Netherlands.
Thomas FinocchiaroScandinavian Real Heart AB, Västerås, Sweden.
Ina Laura PerkinsScandinavian Real Heart AB, Västerås, Sweden.
Harinderjit GillDepartment of Mechanical Engineering, University of Bath, Bath, UK.
Andrew N CooksonDepartment of Mechanical Engineering, University of Bath, Bath, UK.
Katharine H FraserDepartment of Mechanical Engineering, University of Bath, Bath, UK. K.H.Fraser@bath.ac.uk.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

For those suffering from end-stage biventricular heart failure, and where a heart transplantation is not a viable option, a Total Artificial Heart (TAH) can be used as a bridge to transplant device. The Realheart TAH is a four-chamber artificial heart that uses a positive-displacement pumping technique mimicking the native heart to produce pulsatile flow governed by a pair of bileaflet mechanical heart valves. The aim of this work was to create a method for simulating haemodynamics in positive-displacement blood pumps, using computational fluid dynamics with fluid-structure interaction to eliminate the need for pre-existing in vitro valve motion data, and then use it to investigate the performance of the Realheart TAH across a range of operating conditions. The device was simulated in Ansys Fluent for five cycles at pumping rates of 60, 80, 100 and 120 bpm and at stroke lengths of 19, 21, 23 and 25 mm. The moving components of the device were discretised using an overset meshing approach, a novel blended weak-strong coupling algorithm was used between fluid and structural solvers, and a custom variable time stepping scheme was used to maximise computational efficiency and accuracy. A two-element Windkessel model approximated a physiological pressure response at the outlet. The transient outflow volume flow rate and pressure results were compared against in vitro experiments using a hybrid cardiovascular simulator and showed good agreement, with maximum root mean square errors of 15% and 5% for the flow rates and pressures respectively. Ventricular washout was simulated and showed an increase as cardiac output increased, with a maximum value of 89% after four cycles at 120 bpm 25 mm. Shear stress distribution over time was also measured, showing that no more than [Formula: see text]% of the total volume exceeded 150 Pa at a cardiac output of 7 L/min. This study showed this model to be both accurate and robust across a wide range of operating points, and will enable fast and effective future studies to be undertaken on current and future generations of the Realheart TAH.

Indexed as

Cardiovascular SystemHeart, ArtificialHeart TransplantationHemodynamicsModels, CardiovascularProsthesis DesignPulsatile Flow

Identifiers

PMID37059748
PMCPMC10104863

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.