Evidence map›Paper›PMID 37058184›Full record

ReviewOral radiology2023

Analysis of peri-implant bone defects by using cone beam computed tomography (CBCT): an integrative review.

J A Costa, J M Mendes, F Salazar, J J Pacheco, P Rompante, M I Câmara

Abstract readReview
In one paragraph

Review in Oral radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

J A CostaMedicine and Oral Surgery Department, University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra, Portugal. jose.costa@iucs.cespu.pt.ORCID 0000-0002-8127-5916
J M MendesUNIPRO-Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra, Portugal.ORCID 0000-0001-6920-5838
F SalazarUNIPRO-Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra, Portugal.ORCID 0000-0002-6693-4426
J J PachecoUNIPRO-Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra, Portugal.ORCID 0000-0002-0423-0976
P RompanteUNIPRO-Oral Pathology and Rehabilitation Research Unit, University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra, Portugal.ORCID 0000-0003-4932-7437
M I CâmaraMedicine and Oral Surgery Department, University Institute of Health Sciences (IUCS), CESPU, 4585-116, Gandra, Portugal.ORCID 0000-0002-9551-5407

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The objective of this work was to perform an integrative review of the inspection of peri-implant bone defects using cone beam computed tomography (CBCT). An electronic search was performed in the PubMed database using the following scientific terms: CBCT or Cone Beam computed tomography; dental implant; peri-implant; bone loss; defects. The survey identified 267 studies, of which 18 were considered relevant to this study. These studies provided important data taking into account the accuracy of cone beam computed tomography in the detection and measurement of peri-implant bone defects such as fenestrations, dehiscence and intraosseous circumferential defects. The effectiveness of CBCT in aiding in geometric bone calculations and in the diagnosis of peri-implant defects was influenced by factors such as artefacts, defect size, bone wall thickness, implant material, adjustment of acquisition parameters and observer experience. A not insignificant number of studies compared intraoral radiography to CBCT in the detection of peri-implant bone loss. CBCT was clearly superior to intraoral radiography in the detection of all peri-implant bone defects, except for defects located in the interproximal zone. In general, studies have shown that peri-implant bone measurements adjacent to the implant surface can be correctly determined, as well as the diagnosis of peri-implant bone defects with an average discrepancy of less than 1 mm from the actual measurement of the defect.

Indexed as

Spiral Cone-Beam Computed TomographyArtifactsBone and BonesCone-Beam Computed TomographyBone lossCBCTCone-beam computed tomographyDental implantPeri-implant

Identifiers

PMID37058184
PMCPMC10244286

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked