Evidence map›Paper›PMID 37057982›Full record

ArticleRadiation research2023

RENEB Inter-Laboratory Comparison 2021: The Gene Expression Assay.

M Abend, S A Amundson, C Badie, K Brzoska, R Kriehuber, J Lacombe, M Lopez-Riego, K Lumniczky, D Endesfelder, G O'Brien and 16 more

Open access · bronzeAbstract read
In one paragraph

Article in Radiation research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
4.9field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

26 authors at 9 institutions in 4 countries.

M AbendBundeswehr Institute of Radiobiology, Munich, Germany.
S A AmundsonColumbia University Irving Medical Center, Center for Radiological Research, New York, New York.
C BadieUK Health Security Agency and Office for Health Improvement and Disparities, Centre for Radiation, Chemical and Environmental Hazards, Oxfordshire, England.
K BrzoskaInstitute of Nuclear Chemistry and Technology, Centre for Radiobiology and Biological Dosimetry, Warsaw, Poland.
R KriehuberForschungszentrum Jülich, Department of Safety and Radiation Protection, Jülich, Germany.
J LacombeUniversity of Arizona, Center for Applied Nanobioscience & Medicine, Phoenix, Arizona.
M Lopez-RiegoDepartment of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, Stockholm, Sweden.
K LumniczkyRadiation Medicine Unit, Department of Radiobiology and Radiohygiene, National Public Health Centre, Budapest, Hungary.
D EndesfelderBundesamt für Strahlenschutz, BfS, Oberschleißheim, Germany.
G O'BrienUK Health Security Agency and Office for Health Improvement and Disparities, Centre for Radiation, Chemical and Environmental Hazards, Oxfordshire, England.
S Doucha-SenfBundeswehr Institute of Radiobiology, Munich, Germany.
S A GhandhiColumbia University Irving Medical Center, Center for Radiological Research, New York, New York.
R HargitaiRadiation Medicine Unit, Department of Radiobiology and Radiohygiene, National Public Health Centre, Budapest, Hungary.
E KisRadiation Medicine Unit, Department of Radiobiology and Radiohygiene, National Public Health Centre, Budapest, Hungary.
L LundholmDepartment of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, Stockholm, Sweden.
D OskampForschungszentrum Jülich, Department of Safety and Radiation Protection, Jülich, Germany.
P OstheimBundeswehr Institute of Radiobiology, Munich, Germany.
S SchüleBundeswehr Institute of Radiobiology, Munich, Germany.
D SchwankeBundeswehr Institute of Radiobiology, Munich, Germany.
I ShuryakColumbia University Irving Medical Center, Center for Radiological Research, New York, New York.
C SiebenwithBundeswehr Institute of Radiobiology, Munich, Germany.
M Unverricht-YeboahForschungszentrum Jülich, Department of Safety and Radiation Protection, Jülich, Germany.
A WojcikDepartment of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, Stockholm, Sweden.
J YangUniversity of Arizona, Center for Applied Nanobioscience & Medicine, Phoenix, Arizona.
F ZenhausernUniversity of Arizona, Center for Applied Nanobioscience & Medicine, Phoenix, Arizona.
M PortBundeswehr Institute of Radiobiology, Munich, Germany.
Institut für Radiobiologie der BundeswehrColumbia University Irving Medical Center · USForschungszentrum Jülich · DEStockholm University · SEUniversity of Arizona · USBundeswehr Medical Service Academy · DEOffice for Health Improvement and DisparitiesFederal Office for Radiation Protection · DEInstytut Chemii i Techniki Jądrowej · PL

Funding

Sample Engineering CoreU19AI067773 · NIAID · COLUMBIA UNIVERSITY HEALTH SCIENCES · PI FORNACE, ALBERT J · 2005 to 2024
$105.4M
Department of HealthNIAID NIH HHS U19 AI067773
6 · The paper itself

Abstract

Early and high-throughput individual dose estimates are essential following large-scale radiation exposure events. In the context of the Running the European Network for Biodosimetry and Physical Dosimetry (RENEB) 2021 exercise, gene expression assays were conducted and their corresponding performance for dose-assessment is presented in this publication. Three blinded, coded whole blood samples from healthy donors were exposed to 0, 1.2 and 3.5 Gy X-ray doses (240 kVp, 1 Gy/min) using the X-ray source Yxlon. These exposures correspond to clinically relevant groups of unexposed, low dose (no severe acute health effects expected) and high dose exposed individuals (requiring early intensive medical health care). Samples were sent to eight teams for dose estimation and identification of clinically relevant groups. For quantitative reverse transcription polymerase chain reaction (qRT-PCR) and microarray analyses, samples were lysed, stored at 20°C and shipped on wet ice. RNA isolations and assays were run in each laboratory according to locally established protocols. The time-to-result for both rough early and more precise later reports has been documented where possible. Accuracy of dose estimates was calculated as the difference between estimated and reference doses for all doses (summed absolute difference, SAD) and by determining the number of correctly reported dose estimates that were defined as ±0.5 Gy for reference doses <2.5 Gy and ±1.0 Gy for reference doses >3 Gy, as recommended for triage dosimetry. We also examined the allocation of dose estimates to clinically/diagnostically relevant exposure groups. Altogether, 105 dose estimates were reported by the eight teams, and the earliest report times on dose categories and estimates were 5 h and 9 h, respectively. The coefficient of variation for 85% of all 436 qRT-PCR measurements did not exceed 10%. One team reported dose estimates that systematically deviated several-fold from reported dose estimates, and these outliers were excluded from further analysis. Teams employing a combination of several genes generated about two-times lower median SADs (0.8 Gy) compared to dose estimates based on single genes only (1.7 Gy). When considering the uncertainty intervals for triage dosimetry, dose estimates of all teams together were correctly reported in 100% of the 0 Gy, 50% of the 1.2 Gy and 50% of the 3.5 Gy exposed samples. The order of dose estimates (from lowest to highest) corresponding to three dose categories (unexposed, low dose and highest exposure) were correctly reported by all teams and all chosen genes or gene combinations. Furthermore, if teams reported no exposure or an exposure >3.5 Gy, it was always correctly allocated to the unexposed and the highly exposed group, while low exposed (1.2 Gy) samples sometimes could not be discriminated from highly (3.5 Gy) exposed samples. All teams used FDXR and 78.1% of correct dose estimates used FDXR as one of the predictors. Still, the accuracy of reported dose estimates based on FDXR differed considerably among teams with one team's SAD (0.5 Gy) being comparable to the dose accuracy employing a combination of genes. Using the workflow of this reference team, we performed additional experiments after the exercise on residual RNA and cDNA sent by six teams to the reference team. All samples were processed similarly with the intention to improve the accuracy of dose estimates when employing the same workflow. Re-evaluated dose estimates improved for half of the samples and worsened for the others. In conclusion, this inter-laboratory comparison exercise enabled (1) identification of technical problems and corrections in preparations for future events, (2) confirmed the early and high-throughput capabilities of gene expression, (3) emphasized different biodosimetry approaches using either only FDXR or a gene combination, (4) indicated some improvements in dose estimation with FDXR when employing a similar methodology, which requires further research for the final conclusion and (5) underlined the applicability of gene expression for identification of unexposed and highly exposed samples, supporting medical management in radiological or nuclear scenarios.

Indexed as

Radiation ExposureRadiometryBiological AssayDose-Response Relationship, RadiationGene ExpressionHumans

Identifiers

PMID37057982
PMCPMC11106736
OpenAlexW4365479061

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.