Evidence map›Paper›PMID 37056579›Full record

ArticleJournal of medical imaging (Bellingham, Wash.)2023

Theoretical comparison and optimization of cadmium telluride and gallium arsenide photon-counting detectors for contrast-enhanced spectral mammography.

Colin Schaeffer, Bahaa Ghammraoui, Katsuyuki Taguchi, Stephen J Glick

Open access · greenAbstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Colin SchaefferUniversity of Florida, Department of Radiology, Gainesville, Florida, United States.ORCID https://orcid.org/0000-0001-9286-5009
Bahaa GhammraouiFDA, Office of Science and Engineering Laboratories (OSEL), Division of Imaging, Diagnostics and Software Reliability (DIDSR), Silver Spring, Maryland, United States.
Katsuyuki TaguchiJohn Hopkins University School of Medicine, Radiological Physics Division, The Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, Maryland, United States.
Stephen J GlickFDA, Office of Science and Engineering Laboratories (OSEL), Division of Imaging, Diagnostics and Software Reliability (DIDSR), Silver Spring, Maryland, United States.ORCID https://orcid.org/0000-0002-1748-5353
Office of Science · USUniversity of Florida · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: Most photon-counting detectors (PCDs) being developed use cadmium telluride (CdTe), which has nonoptimal characteristic x-ray emission with energies in the range used for breast imaging. New PCD using a gallium arsenide (GaAs) has been developed. Since GaAs has characteristic x-rays lower in energy than those of CdTe, it is hypothesized that this new PCD might be beneficial for spectral x-ray breast imaging. Approach: We performed simulations using realistic mammography x-ray spectra with both CdTe and GaAs PCDs. Five different experiments were conducted, each comparing the performance of CdTe and GaAs: (1) sensitivity of iodine quantification to charge cloud size and electronic noise, (2) effect of photon spectrum on iodine quantification, (3) effect of varying the number of energy bins, (4) a dose analysis to assess any possible dose reduction from using either detector, and (5) spectral performance of ideal CdTe and GaAs PCDs. For each study, 3 sets of 5000 noise realizations were used to calculate the Cramer-Rao lower bound (CRLB) of iodine quantification. Results: For all spectra studied, GaAs gave a lower CRLB for iodine quantification, with 10 of the 12 spectra showing a statistically significant difference ( Conclusion: GaAs is a promising detector material for contrast-enhanced spectral mammography that offers better spectral performance than CdTe.

Indexed as

breast-imagingphoton-countingspectral

Identifiers

PMID37056579
PMCPMC10088557
OpenAlexW4364381377

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.