Evidence map›Paper›PMID 37056302›Full record

ArticleMedical devices (Auckland, N.Z.)2023

Reduction of Eyedrop Volume for Topical Ophthalmic Medications with the Nanodropper Bottle Adaptor.

Deidre M St Peter, Jennifer S Steger, Jennifer L Patnaik, Nicole Davis, Malik Y Kahook, Leonard K Seibold

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in Medical devices (Auckland, N.Z.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06636708 (Evaluation of Nanodropper-mediated Microdrops vs. Standard Drops of 0.5% Proparacaine HCl), which is not on this map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.1field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06636708 phase4completednot on this mapstarted 2024, after this paper: background citation

Evaluation of Nanodropper-mediated Microdrops vs. Standard Drops of 0.5% Proparacaine HCl

TypeinterventionalSponsorColumbia UniversityRan2024 to 2025Enrolled56ConditionsCorneal Diseases, Effectiveness of MicrodropsArmsNanodropper and Proparacaine HCl 0.5%, Standard Eye Drop Bottle with Proparacaine HCl 0.5%
3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Deidre M St PeterDepartment of Ophthalmology, University of Colorado School of Medicine, Aurora, CO, USA.ORCID 0000-0002-8054-4942
Jennifer S StegerNanodropper, Inc, Rochester, MN, USA.
Jennifer L PatnaikDepartment of Ophthalmology, University of Colorado School of Medicine, Aurora, CO, USA.
Nicole DavisDepartment of Ophthalmology, University of Colorado School of Medicine, Aurora, CO, USA.
Malik Y KahookDepartment of Ophthalmology, University of Colorado School of Medicine, Aurora, CO, USA.
Leonard K SeiboldDepartment of Ophthalmology, University of Colorado School of Medicine, Aurora, CO, USA.
University of Colorado Denver · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To determine the drop volume and total number of dispensed drops using the Nanodropper eyedrop bottle adaptor (Nanodropper, Inc.) compared to drops dispensed from stock bottles to potentially limit ocular toxicity of these eyedrops and prolong bottle use. Patients and Methods: Six topical ocular hypotensive medications (5 solutions, 1 suspension), one steroid (suspension) and two artificial tears emulsions were selected for this study. An analytical balance was used to determine the mass per 10 drops with and without the volume-reducing adaptor and repeated until the bottles were completely emptied. The density of each product was determined using the calculated density. The average drop volume and number of drops per bottle for the nine medications were compared with and without the adaptor with paired t-testing. Results: When all medications were assessed, the drops delivered with the adaptor were 62.1% smaller than eyedrops administered from standard bottles. Compared to stock bottle eyedrops, which had a mean volume of 39.8 ± 2.1 μL, the adaptor resulted in drops with a mean volume of 15.1 ± 1.0 μL, p<0.0001. The adaptor delivered 2.6x the number of drops dispensed from a standard 2.5 mL bottle (184.1 ± 15.1 drops with adaptor and 69.8 ± 4.9 drops from stock bottle, p<0.0001). Conclusion: The Nanodropper eyedrop bottle adaptor can significantly reduce drop volume and increase the overall number of drops dispensed compared with stock eyedrop bottles. Further studies are needed to elucidate the clinical impact of utilizing decreased drop volume with direct comparison to current standards of care.

Indexed as

drop assist devicesdry eye syndromeglaucoma medicationsmedication adherencemedication deliveryophthalmic medication

Identifiers

PMID37056302
PMCPMC10086215
OpenAlexW4362669983

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.