Evidence map›Paper›PMID 37055739›Full record

ArticleBMC musculoskeletal disorders2023

Hybrid pedicle screw and modified cortical bone trajectory technique in transforaminal lumbar interbody fusion at L4-L5 segment: finite element analysis.

Alafate Kahaer, Rui Zhang, Yixi Wang, Haopeng Luan, Abulikemu Maimaiti, Dongshan Liu, Wenjie Shi, Tao Zhang, Hailong Guo, Paerhati Rexiti

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
3.1field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Alafate KahaerDepartment of Spine Surgery, The First Affiliated Hospital of Xinjiang Medical University, 137 Liyushan Road, Urumqi, China.
Rui ZhangDepartment of Spine Surgery, The First Affiliated Hospital of Xinjiang Medical University, 137 Liyushan Road, Urumqi, China.
Yixi WangFirst Clinical Medical Institution, Xinjiang Medical University, Urumqi, China.
Haopeng LuanDepartment of Spine Surgery, The First Affiliated Hospital of Xinjiang Medical University, 137 Liyushan Road, Urumqi, China.
Abulikemu MaimaitiDepartment of Spine Surgery, The First Affiliated Hospital of Xinjiang Medical University, 137 Liyushan Road, Urumqi, China.
Dongshan LiuDepartment of Spine Surgery, The First Affiliated Hospital of Xinjiang Medical University, 137 Liyushan Road, Urumqi, China.
Wenjie ShiFirst Clinical Medical Institution, Xinjiang Medical University, Urumqi, China.
Tao ZhangDigital Orthopaedic Center of Xinjiang Medical University, Urumqi, China.
Hailong GuoDepartment of Spine Surgery, The First Affiliated Hospital of Xinjiang Medical University, 137 Liyushan Road, Urumqi, China.
Paerhati RexitiDepartment of Spine Surgery, The First Affiliated Hospital of Xinjiang Medical University, 137 Liyushan Road, Urumqi, China. parhart@vip.sina.com.
Xinjiang Medical University · CNFirst Affiliated Hospital of Xinjiang Medical University · CN

Funding

Central-class Public Welfare Research Institute Project of Chinese Academy of Medical Sciences 2022-JKCS-19
6 · The paper itself

Abstract

backgroundInvestigate the biomechanical properties of the hybrid fixation technique with bilateral pedicle screw (BPS) and bilateral modified cortical bone trajectory screw (BMCS) in L4-L5 transforaminal lumbar interbody fusion (TLIF).

methodsThree finite element (FE) models of the L1-S1 lumbar spine were established according to the three human cadaveric lumbar specimens. BPS-BMCS (BPS at L4 and BMCS at L5), BMCS-BPS (BMCS at L4 and BPS at L5), BPS-BPS (BPS at L4 and L5), and BMCS-BMCS (BMCS at L4 and L5) were implanted into the L4-L5 segment of each FE model. The range of motion (ROM) of the L4-L5 segment, von Mises stress of the fixation, intervertebral cage, and rod were compared under a 400-N compressive load with 7.5 Nm moments in flexion, extension, bending, and rotation.

resultsBPS-BMCS technique has the lowest ROM in extension and rotation, and BMCS-BMCS technique has the lowest ROM in flexion and lateral bending. The BMCS-BMCS technique showed maximal cage stress in flexion and lateral bending, and the BPS-BPS technique in extension and rotation. Compared to the BPS-BPS and BMCS-BMCS technique, BPS-BMCS technique presented a lower risk of screw breakage and BMCS-BPS technique presented a lower risk of rod breakage.

conclusionThe results of this study support that the use of the BPS-BMCS and BMCS-BPS techniques in TLIF surgery for offering the superior stability and a lower risk of cage subsidence and instrument-related complication.

Indexed as

Pedicle ScrewsSpinal FusionBiomechanical PhenomenaCortical BoneFinite Element AnalysisHumansLumbar VertebraeRange of Motion, ArticularFinite element analysisHybrid fixationModified cortical bone trajectoryPedicle screwTransforaminal lumbar interbody fusion

Identifiers

PMID37055739
PMCPMC10099636
OpenAlexW4365451920

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.