ArticleJAMA otolaryngology-- head & neck surgery2023
Evaluation of Surgeon-Performed Ultrasonography With or Without Contrast Enhancement vs Scintigraphy in Patients With Primary Hyperparathyroidism.
Article in JAMA otolaryngology-- head & neck surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 7 citations in OpenAlex.
- Optimizing Parathyroid Localization in Real Life: The Role of Expert-Performed Ultrasonography.Clinical endocrinology · 2026Article
- Ectopic parathyroid adenomas in primary hyperparathyroidism: anatomical classifications, localization strategies, and case series.International journal of surgery (London, England) · 2026Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Importance: Scintigraphy and ultrasonography are common imaging modalities for the preoperative localization of enlarged parathyroid glands in primary hyperparathyroidism. When comparing the 2 modalities, the benefits of ultrasonography in terms of convenience, patient comfort, duration, cost, and lack of radiation should be taken into account. Objective: To investigate whether surgeon-performed ultrasonography, with or without contrast-enhanced ultrasonography (CEUS), is noninferior to scintigraphy for localizing pathological parathyroid glands in patients with primary hyperparathyroidism. Design, Setting, and Participants: Prospective, paired, noninferiority cohort study performed at a high-volume tertiary referral center for parathyroidectomy with blinded examiners and a 6-month follow-up. Participants were adults (age ≥18 years) referred for parathyroidectomy due to primary hyperparathyroidism. Of 207 eligible patients, 35 were excluded, leaving 172 enrolled in the study. Inclusion lasted from September 2019 until February 2021. Follow-up ended in December 2021. Exposures: 99mTechnetium-pertechnetate/99mtechnetium-sestamibi subtraction scintigraphy with 99mtechnetium-sestamibi single-photon emission computed tomography/computed tomography, followed by surgeon-performed ultrasonography and CEUS. Main Outcomes and Measures: The sensitivity of each imaging modality in localizing pathological parathyroid glands, calculated on a per-quadrant and a per-patient basis, respectively. The a priori noninferiority margin was a lower 95% confidence limit for the difference in sensitivity not falling below -10%. Results: Out of 172 participants, 139 (80.8%) were women, the median (range) age was 65 (24-87) years, and the median (IQR) follow-up was 200.5 (181-280.25) days. Quadrant sensitivity (95% CI) was 70.9% (63.2%-78.5%) for ultrasonography, 68.4% (60.4%-76.5%) for ultrasonography plus CEUS, and 67.0% (60.0%-74.0%) for scintigraphy. The sensitivity difference (95% CI) compared with scintigraphy was 3.9% (-4.1% to 11.8%) for ultrasonography and 1.5% (-6.4% to 9.3%) for ultrasonography plus CEUS, establishing noninferiority for both modalities. Per-patient sensitivity was 81.4% (74.8%-86.9%) for ultrasonography and 79.1% (72.2%-84.9%) for both scintigraphy and ultrasonography plus CEUS. The sensitivity difference compared with scintigraphy was 2.3% (-6.8% to 11.4%) for ultrasonography and 0.0% (-9.1% to 9.1%) for ultrasonography plus CEUS, establishing noninferiority for both modalities. Conclusions and Relevance: In this cohort study, conventional ultrasonography by an experienced parathyroid surgeon-sonographer was noninferior to scintigraphy and may constitute a valid first-line imaging modality in patients with primary hyperparathyroidism, even without the addition of CEUS. Further imaging should be reserved for cases that are equivocal or nonlocalizing on ultrasonography.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.