Validation of a Custom Interface Pressure Measurement System to Improve Fitting of Transtibial Prosthetic Check Sockets.

Lucy Armitage, Kenny Cho, Emre Sariyildiz, Angela Buller, Stephen O'Brien, Lauren Kark

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Lucy ArmitageSchool of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW 2522, Australia.ORCID 0000-0001-7837-0640
Kenny ChoSchool of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW 2522, Australia.
Emre SariyildizSchool of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, NSW 2522, Australia.ORCID 0000-0002-4528-2545
Angela BullerOrthopaedic Appliances, Pty, Ltd. (OAPL), Alexandria, NSW 2015, Australia.
Stephen O'BrienGraduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia.
Lauren KarkGraduate School of Biomedical Engineering, University of New South Wales, Sydney, NSW 2052, Australia.
University of Wollongong · AUUNSW Sydney · AU

Funding

University of Wollongong IV003
6 · The paper itself

Abstract

Achievement of fit between the residual limb and prosthetic socket during socket manufacture is a priority for clinicians and is essential for safety. Clinicians have recognised the potential benefits of having a sensor system that can provide objective socket-limb interface pressure measurements during socket fitting, but the cost of existing systems makes current technology prohibitive. This study will report on the characterisation, validation and preliminary clinical implementation of a low cost, portable, wireless sensor system designed for use during socket manufacture. Characterisation and benchtop testing demonstrated acceptable accuracy, behaviour at variable temperature, and dynamic response for use in prosthetic socket applications. Our sensor system was validated with simultaneous measurement by a commercial sensor system in the sockets of three transtibial prosthesis users during a fitting session in the clinic. There were no statistically significant differences between the sensor system and the commercial sensor for a variety of functional activities. The sensor system was found to be valid in this clinical context. Future work should explore how pressure data relates to ratings of fit and comfort, and how objective pressure data might be used to assist in clinical decision making.

Indexed as

Artificial LimbsAmputation StumpsExtremitiesProsthesis Designamputationinterface pressureprosthetic socket

Identifiers

PMID37050838
PMCPMC10099032
OpenAlexW4362700830

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.