Evidence map›Paper›PMID 37050755›Full record

ArticleSensors (Basel, Switzerland)2023

Thin and Scalable Hybrid Emission Filter via Plasma Etching for Low-Invasive Fluorescence Detection.

Erus Rustami, Kiyotaka Sasagawa, Kenji Sugie, Yasumi Ohta, Hironari Takehara, Makito Haruta, Hiroyuki Tashiro, Jun Ohta

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Erus RustamiDivision of Materials Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Japan.ORCID 0000-0002-9288-2455
Kiyotaka SasagawaDivision of Materials Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Japan.ORCID 0000-0002-5718-3958
Kenji SugieDivision of Materials Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Japan.ORCID 0000-0001-7313-7962
Yasumi OhtaDivision of Materials Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Japan.ORCID 0000-0002-0333-4626
Hironari TakeharaDivision of Materials Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Japan.ORCID 0000-0001-7689-1186
Makito HarutaDivision of Materials Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Japan.ORCID 0000-0002-7155-9018
Hiroyuki TashiroDivision of Materials Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Japan.ORCID 0000-0001-5669-154X
Jun OhtaDivision of Materials Science, Graduate School of Science and Technology, Nara Institute of Science and Technology, 8916-5 Takayama, Ikoma 630-0192, Japan.ORCID 0000-0001-8194-9020

Funding

Japan Society for the Promotion of Science JP18H03780Japan Society for the Promotion of Science JP21H03809
6 · The paper itself

Abstract

Hybrid emission filters, comprising an interference filter and an absorption filter, exhibit high excitation light rejection performance and can act as lensless fluorescent devices. However, it has been challenging to produce them in large batches over a large area. In this study, we propose and demonstrate a method for transferring a Si substrate, on which the hybrid filter is deposited, onto an image sensor by attaching it to the sensor and removing the substrate via plasma etching. Through this method, we can transfer uniform filters onto fine micrometer-sized needle devices and millimeter-sized multisensor chips. Optical evaluation reveals that the hybrid filter emits light in the 500 to 560 nm range, close to the emission region of green fluorescent protein (GFP). Furthermore, by observing the fluorescence emission from the microbeads, a spatial resolution of 12.11 μm is calculated. In vitro experiments confirm that the fabricated device is able to discriminate GFP emission patterns from brain slices.

Indexed as

contact imagingemission filterfluorescent imagingimage sensorimplantable deviceoptical filter fabrication

Identifiers

PMID37050755
PMCPMC10098729

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.