Evidence map›Paper›PMID 37050692›Full record

ArticleSensors (Basel, Switzerland)2023

Estimation of Respiratory Rate during Biking with a Single Sensor Functional Near-Infrared Spectroscopy (fNIRS) System.

Mohammad Shahbakhti, Naser Hakimi, Jörn M Horschig, Marianne Floor-Westerdijk, Jurgen Claassen, Willy N J M Colier

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mohammad ShahbakhtiArtinis Medical Systems, B.V., Einsteinweg 17, 6662 PW Elst, The Netherlands.ORCID 0000-0001-6625-7923
Naser HakimiArtinis Medical Systems, B.V., Einsteinweg 17, 6662 PW Elst, The Netherlands.ORCID 0000-0002-2751-1586
Jörn M HorschigArtinis Medical Systems, B.V., Einsteinweg 17, 6662 PW Elst, The Netherlands.ORCID 0000-0002-0159-431X
Marianne Floor-WesterdijkArtinis Medical Systems, B.V., Einsteinweg 17, 6662 PW Elst, The Netherlands.
Jurgen ClaassenDonders Institute for Brain, Cognition and Behaviour, Radboud University, Houtlaan 4, 6525 XZ Nijmegen, The Netherlands.
Willy N J M ColierArtinis Medical Systems, B.V., Einsteinweg 17, 6662 PW Elst, The Netherlands.

Funding

European Regional Development Fund PROJ-01003Horizon 2020 Framework Programme No. 813234 and No. 813843
6 · The paper itself

Abstract

objectiveThe employment of wearable systems for continuous monitoring of vital signs is increasing. However, due to substantial susceptibility of conventional bio-signals recorded by wearable systems to motion artifacts, estimation of the respiratory rate (RR) during physical activities is a challenging task. Alternatively, functional Near-Infrared Spectroscopy (fNIRS) can be used, which has been proven less vulnerable to the subject's movements. This paper proposes a fusion-based method for estimating RR during bicycling from fNIRS signals recorded by a wearable system.

methodsFirstly, five respiratory modulations are extracted, based on amplitude, frequency, and intensity of the oxygenated hemoglobin concentration (O2Hb) signal. Secondly, the dominant frequency of each modulation is computed using the fast Fourier transform. Finally, dominant frequencies of all modulations are fused, based on averaging, to estimate RR. The performance of the proposed method was validated on 22 young healthy subjects, whose respiratory and fNIRS signals were simultaneously recorded during a bicycling task, and compared against a zero delay Fourier domain band-pass filter.

resultsThe comparison between results obtained by the proposed method and band-pass filtering indicated the superiority of the former, with a lower mean absolute error (3.66 vs. 11.06 breaths per minute, p<0.05). The proposed fusion strategy also outperformed RR estimations based on the analysis of individual modulation. SIGNIFICANCE: This study orients towards the practical limitations of traditional bio-signals for RR estimation during physical activities.

Indexed as

BicyclingRespiratory RateHumansMovementOxyhemoglobinsSpectroscopy, Near-InfraredOxyhemoglobinsfNIRSphysical activityrespiratory ratewearable

Identifiers

PMID37050692
PMCPMC10099192

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.