Observational studySensors (Basel, Switzerland)2023
Accuracy of Intracranial Pressure Monitoring-Single Centre Observational Study and Literature Review.
Observational study in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Dual intracranial pressure monitoring in neuro-ICU patients : A retrospective observational study.Neurosurgical review · 2026Observational
- Altered Neurocritical Care Management of Patients with Severe Traumatic Brain Injury Following Changed Positions of the Zero-Reference Points for Intracranial and Arterial Pressure Measurement.Neurocritical care · 2026Article
- Management of intracranial hypertension with and without invasive intracranial pressure monitoring.World journal of critical care medicine · 2025Review
- Mind the drain: expanding TIMING-ICP discussion.Critical care (London, England) · 2025Article
- Evaluating the efficacy and safety of Anlotinib in conjunction with stereotactic radiosurgery for small cell lung cancer patients with brain metastases.Oncology research · 2025Article
- Optical approaches for neurocritical care: Toward non-invasive recording of cerebral physiology in acute brain injury.Neurotherapeutics : the journal of the American Society for Experimental NeuroTherapeutics · 2025Review
- Correlation Between Volume and Pressure of Intracranial Space With Craniectomy Surface Area and Brain Herniation: A Phantom-Based Study.Neurotrauma reports · 2024Article
- Intracranial Pressure Monitoring and Treatment Thresholds in Acute Neural Injury: A Narrative Review of the Historical Achievements, Current State, and Future Perspectives.Neurotrauma reports · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Intracranial hypertension and adequacy of brain blood flow are primary concerns following traumatic brain injury. Intracranial pressure (ICP) monitoring is a critical diagnostic tool in neurocritical care. However, all ICP sensors, irrespective of design, are subject to systematic and random measurement inaccuracies that can affect patient care if overlooked or disregarded. The wide choice of sensors available to surgeons raises questions about performance and suitability for treatment. This observational study offers a critical review of the clinical and experimental assessment of ICP sensor accuracy and comments on the relationship between actual clinical performance, bench testing, and manufacturer specifications. Critically, on this basis, the study offers guidelines for the selection of ICP monitoring technologies, an important clinical decision. To complement this, a literature review on important ICP monitoring considerations was included. This study utilises illustrative clinical and laboratory material from 1200 TBI patients (collected from 1992 to 2019) to present several important points regarding the accuracy of in vivo implementation of contemporary ICP transducers. In addition, a thorough literature search was performed, with sources dating from 1960 to 2021. Sources considered to be relevant matched the keywords: "intraparenchymal ICP sensors", "fiberoptic ICP sensors", "piezoelectric strain gauge sensors", "external ventricular drains", "CSF reference pressure", "ICP zero drift", and "ICP measurement accuracy". Based on single centre observations and the 76 sources reviewed in this paper, this material reports an overall anticipated measurement accuracy for intraparenchymal transducers of around ± 6.0 mm Hg with an average zero drift of <2.0 mm Hg. Precise ICP monitoring is a key tenet of neurocritical care, and accounting for zero drift is vital. Intraparenchymal piezoelectric strain gauge sensors are commonly implanted to monitor ICP. Laboratory bench testing results can differ from in vivo observations, revealing the shortcomings of current ICP sensors.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials