Evidence map›Paper›PMID 37047866›Full record

ArticleInternational journal of environmental research and public health2023

The Importance of a Distance between the Lines Encircling Pulmonary Veins in Atrial Fibrillation Ablation on First-Pass Isolation Ratio and Clinical Outcomes.

Krystian Krzyżanowski, Marek Kiliszek, Beata Uziębło-Życzkowska, Magdalena Smalc-Stasiak, Aleksandra Winkler, Paweł Krzesiński

Open access · goldAbstract read
In one paragraph

Article in International journal of environmental research and public health, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Krystian KrzyżanowskiDepartment of Cardiology and Internal Diseases, Military Institute of Medicine, 04-141 Warsaw, Poland.
Marek KiliszekDepartment of Cardiology and Internal Diseases, Military Institute of Medicine, 04-141 Warsaw, Poland.ORCID 0000-0002-7935-1756
Beata Uziębło-ŻyczkowskaDepartment of Cardiology and Internal Diseases, Military Institute of Medicine, 04-141 Warsaw, Poland.ORCID 0000-0001-8997-6568
Magdalena Smalc-StasiakDepartment of Cardiology and Internal Diseases, Military Institute of Medicine, 04-141 Warsaw, Poland.
Aleksandra WinklerDepartment of Cardiology and Internal Diseases, Military Institute of Medicine, 04-141 Warsaw, Poland.
Paweł KrzesińskiDepartment of Cardiology and Internal Diseases, Military Institute of Medicine, 04-141 Warsaw, Poland.ORCID 0000-0003-1909-0993
Wojskowy Instytut Medycyny Lotniczej · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionHow wide the encircling line is made may influence the outcomes of pulmonary vein isolation (PVI). In the present study we hypothesised that the distance between the lines encircling the pulmonary veins may correspond with the extent of wide antral circumferential ablation (WACA). The aim of the study was to assess the impact of the distance and the area between the lines on the posterior wall of the left atrium on first-pass isolation rate and 12-month freedom from atrial arrhythmia in patients undergoing PVI ablation. METHODS AND

resultsOne hundred sixteen patients underwent circumferential ablation index (AI)-guided PVI. The distance between the encircling ablation lines was measured off-line between the uppermost points (right and left) and the lowest points and as the area between the encircling lines on the posterior wall. The first-pass isolation rate and 12-month freedom from atrial arrhythmia were 59% and 73%, respectively. Distance between the encircling lines measured linearly or as the area of the posterior wall, assessed as direct values or indexed to left atrial dimensions, did not differ between patients with and without first-pass isolation or between patients with and without recurrences of atrial arrhythmia.

conclusionsThe distance between the ablation lines did not influence the rate of first-pass isolation and arrhythmia recurrence in the long-term follow-up after PVI procedures incorporating the ablation index protocol.

Indexed as

Atrial FibrillationCatheter AblationPulmonary VeinsHeart AtriaHumansRecurrenceTreatment Outcomeablationatrial fibrillationposterior wallpulmonary vein isolationwide antral circumferential ablation

Identifiers

PMID37047866
PMCPMC10094726
OpenAlexW4360860824

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.