Evidence map›Paper›PMID 37046776›Full record

ArticleCancers2023

Radiologic versus Segmentation Measurements to Quantify Wilms Tumor Volume on MRI in Pediatric Patients.

Myrthe A D Buser, Alida F W van der Steeg, Marc H W A Wijnen, Matthijs Fitski, Harm van Tinteren, Marry M van den Heuvel-Eibrink, Annemieke S Littooij, Bas H M van der Velden

Abstract read
In one paragraph

Article in Cancers, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Exploring theFrontiers in physiology · 2025
    Article
  10. Article
  11. Article
  12. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Myrthe A D BuserPrincess Máxima Center for Pediatric Oncology, 3584 CS Utrecht, The Netherlands.ORCID 0000-0003-0640-6434
Alida F W van der SteegPrincess Máxima Center for Pediatric Oncology, 3584 CS Utrecht, The Netherlands.ORCID 0000-0003-0168-7513
Marc H W A WijnenPrincess Máxima Center for Pediatric Oncology, 3584 CS Utrecht, The Netherlands.
Matthijs FitskiPrincess Máxima Center for Pediatric Oncology, 3584 CS Utrecht, The Netherlands.ORCID 0000-0003-0515-7691
Harm van TinterenPrincess Máxima Center for Pediatric Oncology, 3584 CS Utrecht, The Netherlands.ORCID 0000-0002-4626-8702
Marry M van den Heuvel-EibrinkPrincess Máxima Center for Pediatric Oncology, 3584 CS Utrecht, The Netherlands.ORCID 0000-0002-7760-879X
Annemieke S LittooijPrincess Máxima Center for Pediatric Oncology, 3584 CS Utrecht, The Netherlands.
Bas H M van der VeldenImage Sciences Institute, University Medical Center Utrecht, Utrecht University, 3584 CX Utrecht, The Netherlands.ORCID 0000-0003-3750-2824

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Wilms tumor is a common pediatric solid tumor. To evaluate tumor response to chemotherapy and decide whether nephron-sparing surgery is possible, tumor volume measurements based on magnetic resonance imaging (MRI) are important. Currently, radiological volume measurements are based on measuring tumor dimensions in three directions. Manual segmentation-based volume measurements might be more accurate, but this process is time-consuming and user-dependent. The aim of this study was to investigate whether manual segmentation-based volume measurements are more accurate and to explore whether these segmentations can be automated using deep learning. We included the MRI images of 45 Wilms tumor patients (age 0-18 years). First, we compared radiological tumor volumes with manual segmentation-based tumor volume measurements. Next, we created an automated segmentation method by training a nnU-Net in a five-fold cross-validation. Segmentation quality was validated by comparing the automated segmentation with the manually created ground truth segmentations, using Dice scores and the 95th percentile of the Hausdorff distances (HD95). On average, manual tumor segmentations result in larger tumor volumes. For automated segmentation, the median dice was 0.90. The median HD95 was 7.2 mm. We showed that radiological volume measurements underestimated tumor volume by about 10% when compared to manual segmentation-based volume measurements. Deep learning can potentially be used to replace manual segmentation to benefit from accurate volume measurements without time and observer constraints.

Indexed as

deep learningMRIpediatric oncologyvolume measurementsWilms tumor

Identifiers

PMID37046776
PMCPMC10092966

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.