Evidence map›Paper›PMID 37046154›Full record

ArticleRadiological physics and technology2023

Usefulness of copper filters in digital chest radiography based on the relationship between effective detective quantum efficiency and deep learning-based segmentation accuracy of the tumor area.

Shu Onodera, Yohan Kondo, Shoko Ishizawa, Tomoyoshi Kawabata, Hiroki Ishii

Abstract read
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.7field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Shu OnoderaDepartment of Radiology Division of Medical Technology, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan. onodera@rad.hosp.tohoku.ac.jp.ORCID http://orcid.org/0000-0002-5761-6434
Yohan KondoGraduate School of Health Sciences, Niigata University, 746 Asahimachidori 2bancho Chuo-ku, Niigata City, Niigata, 951-8518, Japan.
Shoko IshizawaDepartment of Radiology Division of Medical Technology, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.
Tomoyoshi KawabataDepartment of Radiology Division of Medical Technology, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.
Hiroki IshiiDepartment of Radiology Division of Medical Technology, Tohoku University Hospital, 1-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8574, Japan.
Tohoku University Hospital · JPNiigata University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to determine the optimal radiographic conditions for detecting lesions on digital chest radiographs using an indirect conversion flat-panel detector with a copper (Cu) filter. First, we calculated the effective detective quantum efficiency (DQE) by considering clinical conditions to evaluate the image quality. We then measured the segmentation accuracy using a U-net convolutional network to verify the effectiveness of the Cu filter. We obtained images of simulated lung tumors using 10-mm acrylic spheres positioned at the right lung apex and left middle lung of an adult chest phantom. The Dice coefficient was calculated as the similarity between the output and learning images to evaluate the accuracy of tumor area segmentation using U-net. Our results showed that effective DQE was higher in the following order up to the spatial frequency of 2 cycles/mm: 120 kV + no Cu, 120 kV + Cu 0.1 mm, and 120 kV + Cu 0.2 mm. The segmented region was similar to the true region for mass-area extraction in the left middle lobe. The lesion segmentation in the upper right lobe with 120 kV + no Cu and 120 kV + Cu 0.1 mm was less successful. However, adding a Cu filter yielded reproducible images with high Dice coefficients, regardless of the tumor location. We confirmed that adding a Cu filter decreases the X-ray absorption efficiency while improving the signal-to-noise ratio (SNR). Furthermore, artificial intelligence accurately segments low-contrast lesions.

Indexed as

Deep LearningNeoplasmsArtificial IntelligenceCopperHumansRadiographic Image EnhancementRadiographyCopperBeam qualityChest radiographyCopper filterDeep learningEffective DQE

Identifiers

PMID37046154
OpenAlexW4365141068

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.