Evidence map›Paper›PMID 37043567›Full record

ArticleScience advances2023

Quantum magnetic gradiometer with entangled twin light beams.

Shuhe Wu, Guzhi Bao, Jinxian Guo, Jun Chen, Wei Du, Minwei Shi, Peiyu Yang, Liqing Chen, Weiping Zhang

Open access · goldAbstract read
In one paragraph

Article in Science advances, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
9.1field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 45 citations in OpenAlex.

  1. Article
  2. Quantum twin interferometers.Science advances · 2025
    Article
  3. Article
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 2 countries.

Shuhe WuSchool of Physics and Astronomy, and Tsung-Dao Lee institute, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0000-0001-9508-0338
Guzhi BaoSchool of Physics and Astronomy, and Tsung-Dao Lee institute, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0000-0002-9241-8820
Jinxian GuoSchool of Physics and Astronomy, and Tsung-Dao Lee institute, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0000-0002-0537-5771
Jun ChenSchool of Physics and Astronomy, and Tsung-Dao Lee institute, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0000-0002-7691-447X
Wei DuSchool of Physics and Astronomy, and Tsung-Dao Lee institute, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0000-0001-6415-4170
Minwei ShiSchool of Physics and Astronomy, and Tsung-Dao Lee institute, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0000-0003-4376-8805
Peiyu YangSchool of Physics and Astronomy, and Tsung-Dao Lee institute, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0000-0001-5425-0767
Liqing ChenShanghai Branch, Hefei National Laboratory, Shanghai 201315, China.ORCID 0000-0002-3578-5747
Weiping ZhangSchool of Physics and Astronomy, and Tsung-Dao Lee institute, Shanghai Jiao Tong University, Shanghai 200240, China.ORCID 0000-0001-5098-4042
Shanghai Jiao Tong University · CNEast China Normal University · CNShanxi University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In the past few decades, optical magnetometry has experienced remarkable development and reached to an outstanding sensitivity. For magnetometry based on optical readout of atomic ensemble, the fundamental limitation of sensitivity is restricted by spin projection noise and photon shot noise. Meanwhile, in practical applications, ambient magnetic noise also greatly limits the sensitivity. To achieve the best sensitivity, it is essential to find an efficacious way to eliminate the noises from different sources, simultaneously. Here, we demonstrate a quantum magnetic gradiometer with sub-shot-noise sensitivity using entangled twin beams with differential detection. The quantum enhancement spans a frequency range from 7 Hz to 6 MHz with maximum squeezing of 5.5 dB below the quantum noise limit. The sensitivity of gradiometer reaches 18 fT/cm[Formula: see text] at 20 Hz. Our study inspires future possibilities to use quantum-enhanced technology in developing sensitive magnetometry for practical applications in noisy and physically demanding environments.

Identifiers

PMID37043567
PMCPMC10096575
OpenAlexW4365140310

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked