Evidence map›Paper›PMID 37043202›Full record

ArticleJAMA network open2023

Risk of Recall Associated With Modifications to High-risk Medical Devices Approved Through US Food and Drug Administration Supplements.

Jonathan R Dubin, Jonathan R Enriquez, An-Lin Cheng, Hunter Campbell, Akin Cil

Erratum issuedAbstract read
In one paragraph

Article in JAMA network open, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. FDA Device Approval-What You Were Not Taught in Training.Journal of the Pediatric Orthopaedic Society of North America · 2023
    Review
  7. Error in Author Affiliations.JAMA network open · 2023
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Jonathan R DubinDepartment of Orthopedics, University of Missouri-Kansas City.
Jonathan R EnriquezDepartment of Orthopedics, University of Missouri-Kansas City.
An-Lin ChengResearch and Statistical Consult Service, University of Missouri-Kansas City.
Hunter Campbellcurrently a medical student at University of Missouri-Kansas City School of Medicine.
Akin CilDepartment of Orthopedics, University of Missouri-Kansas City.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Importance: High-risk medical devices approved by the US Food and Drug Administration (FDA) can undergo modifications to their original premarket approval (PMA) via 1 of 5 types of supplements. Only panel track supplements (approximately 1%) require clinical data for approval. The association between device modifications and risk to patient safety has not previously been analyzed. Objective: To determine the association between PMA supplements and the risk of any device recall and high-risk (class 1) recall. Design, Setting, and Participants: In this cohort study, the FDA database was queried for original devices approved via PMA from January 1, 2008, through December 31, 2019. Supplement and recall data were obtained for these devices from January 1, 2008, through December 31, 2021, giving a minimum 2-year follow-up after initial approval. Data were analyzed from July 6 to August 6, 2022. Retrospective, time-to-event analysis investigated the association between the number and type of supplements and risk of recall. Exposures: Supplements submitted by manufacturers for FDA approval to modify devices. Main Outcomes and Measures: A mixed-effects Cox proportional hazards regression model with frailty terms was used, modeling device recall as an outcome variable during the observation period. A second model was performed for class 1 (high-risk) recall. Explanatory variables are the number of supplements, number of panel track supplements, and cardiovascular devices. Multivariable analysis was performed to identify independent risk factors for recall with hazard ratios (HRs) as the main end point. Results: A total of 373 original PMA devices with 10 776 associated supplements were included in the analysis. A median 2.5 (IQR, 1.2-5.0) supplements per device were approved annually. Cardiovascular devices contributed 138 supplements (37.0%), followed by microbiology with 45 (12.1%). No other specialty contributed more than 10%. Multivariable analysis demonstrated that each increase of 1 supplement per year was associated with increased risk of recall (HR, 1.28 [95% CI, 1.15-1.44]; P < .001). For class 1 recall, increased number of supplements (HR, 1.32 [95% CI, 1.06-1.64]; P = .01) and cardiovascular vsnoncardiovascular classification of devices (HR, 3.51 [95% CI, 1.15-10.72]; P = .03) were significantly associated with an increased risk of recall. Conclusions and Relevance: The findings of this cohort study suggest that PMA supplements are associated with an approximately 30% increased risk of any recall and class 1 recall. The FDA processes for approving modifications to high-risk medical devices should be reevaluated to optimize patient safety and public health.

Indexed as

Product Surveillance, PostmarketingCohort StudiesHumansRetrospective StudiesRisk FactorsUnited StatesUnited States Food and Drug Administration

Identifiers

PMID37043202
PMCPMC10099049

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.