Trial reportJAMA network open2023
Aerosol Box Use in Reducing Health Care Worker Contamination During Airway Procedures (AIRWAY Study): A Simulation-Based Randomized Clinical Trial.
Trial report in JAMA network open, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04880668 (Impact of Aerosol Box Use on Patterns of Healthcare Provider and Environmental Contamination During Aerosol Generating Medical Procedures), which is not on this map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Impact of Aerosol Box Use on Patterns of Healthcare Provider and Environmental Contamination During Aerosol Generating Medical Procedures: A Multicenter Study
Who cites it
3 citing papers in PubMed, 7 citations in OpenAlex.
- Article
- Simulation in airway management teaching and training.Indian journal of anaesthesia · 2024Article
- Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
17 authors at 11 institutions in 3 countries.
Funding
Abstract
Importance: The aerosol box has been used during the management of patients with COVID-19 to reduce health care practitioner (HCP) exposure during aerosol-generating medical procedures (AGMPs). Little is known about the effect of aerosol box use on HCP contamination and AGMP procedure time. Objective: To investigate whether use of an aerosol box during AGMPs reduces HCP contamination or influences the time to successful completion and first-pass success rate for endotracheal intubation (ETI) and laryngeal mask airway (LMA) insertion. Design, Setting, and Participants: This multicenter, simulation-based, randomized clinical trial was conducted from May to December 2021 at tertiary care pediatric hospitals. Participant teams performed 3 simulated patient scenarios: bag-valve-mask ventilation, ETI, and LMA insertion. During the scenarios, aerosols were generated using Glo Germ. Teams of 2 HCPs were randomly assigned to control (no aerosol box) or intervention groups (aerosol box). Statistical analysis was performed from July 2022 to February 2023. Interventions: The aerosol box (or SplashGuard CG) is a transparent, plastic barrier covering the patient's head and shoulders with access ports allowing HCPs to manage the airway. Main Outcomes and Measures: The primary outcome was surface area of contamination (AOC) on participants. Secondary outcomes were time to successful completion and first-pass success rates for ETI and LMA insertion. Results: A total of 64 teams (128 participants) were enrolled, with data from 61 teams (122 participants) analyzed. Among the 122 participants analyzed, 79 (64.8%) were female and 85 (69.7%) were physicians. Use of an aerosol box was associated with a 77.5% overall decreased AOC to the torso (95% CI, -86.3% to -62.9%; P < .001) and a 60.7% overall decreased AOC to the facial area (95% CI, -75.2% to -37.8%; P < .001) in airway HCPs. There was no statistically significant difference in surface contamination after doffing personal protective equipment between groups. Time to completing ETI was longer in the aerosol box group compared with the control group (mean difference: 10.2 seconds; 95% CI, 0.2 to 20.2 seconds; P = .04), but there was no difference between groups for LMA insertion (mean difference: 2.4 seconds; 95% CI, -8.7 to 13.5 seconds; P = .67). Conclusions and Relevance: In this randomized clinical trial of aerosol box use in AGMPs, use of an aerosol box reduced contamination deposition on HCPs' torso and face predoffing; the use of an aerosol box delayed time to successful intubation. These results suggest that the incremental benefits of reduced surface contamination from aerosol box use should be weighed against delayed time to complete intubation, which may negatively affect patient outcome. Trial Registration: ClinicalTrials.gov Identifier: NCT04880668.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.