Evidence map›Paper›PMID 37042146›Full record

ArticleBeijing da xue xue bao. Yi xue ban = Journal of Peking University. Health sciences2023

[Effect of various intracanal materials on the diagnostic accuracy of cone-beam computed tomography in vertical root fractures].

J H Zhang, J Pan, Z P Sun, X Wang

Open access · greenAbstract readEnglish Abstract
In one paragraph

Article in Beijing da xue xue bao. Yi xue ban = Journal of Peking University. Health sciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

J H ZhangDepartment of Stomatology, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digi-tal Medical Devices, Beijing 100081, China.
J PanDepartment of Stomatology, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digi-tal Medical Devices, Beijing 100081, China.
Z P SunDepartment of Radiology, Peking University School and Hospital of Stomatology, Beijing 100081, China.
X WangDepartment of Stomatology, Peking University Third Hospital, Beijing 100191, China.
Peking University Third Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo study the effect of various intracanal materials on the accuracy of oral maxillofacial cone-beam computed tomography (CBCT) for the diagnosis of vertical root fracture (VRF).

methodsA total of twenty-four structurally intact single root canal dried and isolated teeth extracted for orthodontic treatment or periodontal disease were collected. The teeth were decrowned along the cemento-enamel junction (CEJ) and then used as samples for the study after conventional root canal preparation and post preparation. The 24 samples were divided into two groups with 12 samples in each group. Group A was the control group (no VRF group). According to intracanal materials, they were divided into five subgroups: blank group, fiber post group, gutta-percha point group, titanium post group and gold-palladium post group. Group B was the experimental group (VRF group), and subgroups were grouped as above. The VRF model was prepared by a unified method in the VRF group: the root was completely fractured in the buccolingual direction with a custom root canal nail and then cemented and reset. The control group was not subjected to the simulation of VRF. Titanium post and gold-palladium post were made according to the individuality of the root canal preparation, and the tightness of the post to the root canal wall was confirmed by X-ray radiograph. Then all the samples were scanned by CBCT in the isolate swine mandibular alveolar sockets. The diagnostic accuracy was statistically analyzed

resultsThe accuracy of the diagnosis of VRF in the blank group, fiber post group, gutta-percha point group, titanium post group, and gold-palladium post group in CBCT was 95.83%, 91.67%, 87.50%, 79.17%, and 45.83%, respectively. Compared with the blank group, the differences were not statistically significant in the fiber post group (

conclusionVarious intracanal materials have different degrees of influence on the diagnostic accuracy of VRF diagnosis in CBCT. The influence of fiber post, gutta-percha point and titanium post was small, while the influence of gold-palladium post was significant.

Indexed as

Cone-Beam Computed TomographyTooth FracturesTooth RootAnimalsGoldGutta-PerchaPalladiumReproducibility of ResultsSwineTitaniumGoldGutta-PerchaPalladiumTitaniumCone-beam computed tomographyIntracanal materialsVertical root fractures

Identifiers

PMID37042146
PMCPMC10091258
OpenAlexW4365135120

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.