Evidence map›Paper›PMID 37042049›Full record

ArticleMedical physics2023

Pie-Net: Prior-information-enabled deep learning noise reduction for coronary CT angiography acquired with a photon counting detector CT.

Shaojie Chang, Nathan R Huber, Jeffrey F Marsh, Emily K Koons, Hao Gong, Lifeng Yu, Cynthia H McCollough, Shuai Leng

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.3field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 12 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Improving Stenosis Assessment in Energy Integrating Detector CT via Learned Monoenergetic Imaging Capability.Proceedings of SPIE--the International Society for Optical Engineering · 2024
    Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Shaojie ChangDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Nathan R HuberDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Jeffrey F MarshDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Emily K KoonsDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Hao GongDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Lifeng YuDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Cynthia H McColloughDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Shuai LengDepartment of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Mayo Clinic · US

Funding

Comprehensive characterization of coronary atherosclerotic disease using photon-counting-detector dual-source CT and its impact on patient managementR01EB028590 · NIBIB · MAYO CLINIC ROCHESTER · PI LENG, SHUAI, MCCOLLOUGH, CYNTHIA H · 2020 to 2023
$2.6M
NIBIB NIH HHS R01 EB028590NIH HHS R01EB028590
6 · The paper itself

Abstract

backgroundPhoton-counting-detector CT (PCD-CT) enables the production of virtual monoenergetic images (VMIs) at a high spatial resolution (HR) via simultaneous acquisition of multi-energy data. However, noise levels in these HR VMIs are markedly increased. PURPOSE: To develop a deep learning technique that utilizes a lower noise VMI as prior information to reduce image noise in HR, PCD-CT coronary CT angiography (CTA).

methodsCoronary CTA exams of 10 patients were acquired using PCD-CT (NAEOTOM Alpha, Siemens Healthineers). A prior-information-enabled neural network (Pie-Net) was developed, treating one lower-noise VMI (e.g., 70 keV) as a prior input and one noisy VMI (e.g., 50 keV or 100 keV) as another. For data preprocessing, noisy VMIs were reconstructed by filtered back-projection (FBP) and iterative reconstruction (IR), which were then subtracted to generate "noise-only" images. Spatial decoupling was applied to the noise-only images to mitigate overfitting and improve randomization. Thicker slice averaging was used for the IR and prior images. The final training inputs for the convolutional neural network (CNN) inside the Pie-Net consisted of thicker-slice signal images with the reinsertion of spatially decoupled noise-only images and the thicker-slice prior images. The CNN training labels consisted of the corresponding thicker-slice label images without noise insertion. Pie-Net's performance was evaluated in terms of image noise, spatial detail preservation, and quantitative accuracy, and compared to a U-net-based method that did not include prior information.

resultsPie-Net provided strong noise reduction, by 95 ± 1% relative to FBP and by 60 ± 8% relative to IR. For HR VMIs at different keV (e.g., 50 keV or 100 keV), Pie-Net maintained spatial and spectral fidelity. The inclusion of prior information from the PCD-CT data in the spectral domain was able to improve a robust deep learning-based denoising performance compared to the U-net-based method, which caused some loss of spatial detail and introduced some artifacts.

conclusionThe proposed Pie-Net achieved substantial noise reduction while preserving HR VMI's spatial and spectral properties.

Indexed as

Computed Tomography AngiographyDeep LearningCoronary AngiographyHumansPhantoms, ImagingTomography, X-Ray Computedcoronary computed tomography angiographydeep learninghigh resolutionnoise reductionphoton counting detector CTprior information

Identifiers

PMID37042049
PMCPMC10564970
OpenAlexW4365136356

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.