Evidence map›Paper›PMID 37041618›Full record

ArticleBMC musculoskeletal disorders2023

Anterior variable-angle locked plating versus tension band wiring of simple and complex patella fractures - a biomechanical investigation.

Karl Stoffel, Ivan Zderic, Torsten Pastor, William Woodburn, Richard Castle, Jessica Penman, Eladio Saura-Sanchez, Boyko Gueorguiev, Christoph Sommer

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Clinical and functional outcomes of locked plating vs. cerclage compression wiring for AO type C patellar fractures- a retrospective single-center cohort study.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024
    Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 5 institutions in 2 countries.

Karl Stoffel *University Hospital Basel, Petersgraben 4, Basel, 4031, Switzerland.
Ivan Zderic *AO Research Institute Davos, Clavadelerstrasse 8, Davos, 7270, Switzerland. ivan.zderic@aofoundation.org.
Torsten PastorAO Research Institute Davos, Clavadelerstrasse 8, Davos, 7270, Switzerland.
William WoodburnDePuy Synthes, Goshen Pkwy, West Chester, PA, 1310, 19380, USA.
Richard CastleDePuy Synthes, Goshen Pkwy, West Chester, PA, 1310, 19380, USA.
Jessica PenmanDePuy Synthes, Goshen Pkwy, West Chester, PA, 1310, 19380, USA.
Eladio Saura-SanchezUniversity Hospital of Elche, Carrer Almazara, 11, Elche, Alicante, 03203, Spain.
Boyko GueorguievAO Research Institute Davos, Clavadelerstrasse 8, Davos, 7270, Switzerland.
Christoph SommerCantonal Hospital Graubünden, Loestrasse 170, Chur, 7000, Switzerland.
AO Foundation · CHHospital General Universitario de Elche · ESKantonsspital Graubünden · CHUniversity Hospital of Basel · CHUniversity of Lucerne · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe aim of this study was to investigate the biomechanical performance of novel anterior variable-angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures.

methodsSixteen pairs of human cadaveric knees were used to simulate two-part simple transverse AO/OTA 34-C1 and five-part complex AO/OTA 34-C3 patella fractures. The complex fracture pattern was characterized with a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral and an inferior fragment mimicking comminution around the distal patella pole. Eight pairs with simple fractures were split for fixation via either tension band wiring (TBW) through two parallel cannulated screws or anterior variable-angle locked plating, whereas other eight pairs with complex fractures were split for either TBW through two parallel cannulated screws plus circumferential cerclage wiring, or anterior variable-angle locked plating using a cortical caudo-cranial polar screw. Each specimen was tested over 5000 cycles with a range of motion from 90° flexion to full extension by pulling on the quadriceps tendon. Interfragmentary movements were captured by motion tracking.

resultsFor both fracture types, the longitudinal and shear articular displacements, measured between the proximal and distal fragments at the central patella aspect between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following anterior variable-angle locked plating versus TBW, p ≤ 0.01.

conclusionsFrom a biomechanical perspective, anterior locked plating of both simple and complex patella fractures resulted in less interfragmentary displacement under extended cyclic loading.

Indexed as

Fractures, BoneKnee InjuriesPatella FractureBiomechanical PhenomenaBone ScrewsFracture Fixation, InternalHumansAnterior variable-angle locked platingBiomechanicsComplex patella fractureSimple patella fractureTension band wiring

Identifiers

PMID37041618
PMCPMC10088273
OpenAlexW4364365882

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.