Biomechanical study of different fixation constructs for anterior column and posterior hemi-transverse acetabular fractures: a finite element analysis.

Kaifang Chen, Guixiong Huang, Yizhou Wan, Sheng Yao, Yanlin Su, Lianxin Li, Xiaodong Guo

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. The infraacetabular screw - anatomy, radiology, biomechanics and clinics.Archives of orthopaedic and trauma surgery · 2024
    Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Kaifang Chen *Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue No.1277, Wuhan, Hubei, 430022, People's Republic of China.
Guixiong Huang *Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue No.1277, Wuhan, Hubei, 430022, People's Republic of China.
Yizhou WanDepartment of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue No.1277, Wuhan, Hubei, 430022, People's Republic of China.
Sheng YaoDepartment of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue No.1277, Wuhan, Hubei, 430022, People's Republic of China.
Yanlin SuDepartment of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue No.1277, Wuhan, Hubei, 430022, People's Republic of China.
Lianxin LiDepartment of Orthopaedics, Shandong Provincial Hospital Affiliated to Shandong University, Jinan, People's Republic of China.
Xiaodong GuoDepartment of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Jiefang Avenue No.1277, Wuhan, Hubei, 430022, People's Republic of China. xiaodongguo@hust.edu.cn.
Huazhong University of Science and Technology · CNUnion Hospital · CNShandong University · CN

Funding

National Key Research and Development Program of China 2016YFC1100100National Natural Science Foundation of China 82202715National Natural Science Foundation of China,China 81371939
6 · The paper itself

Abstract

backgroundTo compare the biomechanical properties and stability, using a finite element model, of four fixation constructs used for the treatment of anterior column and posterior hemi-transverse (ACPHT) acetabular fractures under two physiological loading conditions (standing and sitting).

methodsA finite element model simulating ACPHT acetabular fractures was created for four different scenarios: a suprapectineal plate combined with posterior column and infra-acetabular screws (SP-PS-IS); an infrapectineal plate combined with posterior column and infra-acetabular screws (IP-PS-IS); a special infrapectineal quadrilateral surface buttress plate (IQP); and a suprapectineal plate combined with a posterior column plate (SP-PP). Three-dimensional finite element stress analysis was performed on these models with a load of 700 N in standing and sitting positions. Biomechanical stress distributions and fracture displacements were analysed and compared between these fixation techniques.

resultsIn models simulating the standing position, high displacements and stress distributions were observed at the infra-acetabulum regions. The degree of these fracture displacements was low in the IQP (0.078 mm), as compared to either the IP-PS-IS (0.079 mm) or the SP & PP (0.413 mm) fixation constructs. However, the IP-PS-IS fixation construct had the highest effective stiffness. In models simulating the sitting position, high fracture displacements and stress distributions were observed at the regions of the anterior and posterior columns. The degree of these fracture displacements was low in the SP-PS-IS (0.101 mm), as compared to the IP-PS-IS (0.109 mm) and the SP-PP (0.196 mm) fixation constructs.

conclusionIn both standing and sitting positions, the stability and stiffness index were comparable between the IQP, SP-PS-IS, and IP-PS-IS. These 3 fixation constructs had smaller fracture displacements than the SP-PP construct. The stress concentrations at the regions of quadrilateral surface and infra-acetabulum suggest that the buttressing fixation of quadrilateral plate was required for ACPHT fractures.

Indexed as

Hip FracturesSpinal FracturesBiomechanical PhenomenaBone ScrewsFinite Element AnalysisFracture Fixation, InternalHumansAcetabular fracturesBiomechanicsFinite elementInfrapectineal plateQuadrilateral surface

Identifiers

PMID37041549
PMCPMC10088117
OpenAlexW4364374553

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390