Evidence map›Paper›PMID 37041271›Full record

ArticleClinical oral investigations2023

Predictability of intraoral scanner error for full-arch implant-supported rehabilitation.

Francesco Zingari, Matteo Meglioli, Francesco Gallo, Guido Maria Macaluso, Sara Tagliaferri, Andrea Toffoli, Benedetta Ghezzi, Simone Lumetti

Abstract read
In one paragraph

Article in Clinical oral investigations, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Francesco ZingariCenter of Dental Medicine, Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126, Parma, Italy.
Matteo MeglioliCenter of Dental Medicine, Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126, Parma, Italy.
Francesco GalloDepartment of Biomedical, Surgical and Dental Sciences, School of Dentistry, University of Milan, Milan, Italy.
Guido Maria MacalusoCenter of Dental Medicine, Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126, Parma, Italy. guidomaria.macaluso@unipr.it.
Sara TagliaferriDepartment of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126, Parma, Italy.
Andrea ToffoliCenter of Dental Medicine, Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126, Parma, Italy.
Benedetta GhezziCenter of Dental Medicine, Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126, Parma, Italy.
Simone LumettiCenter of Dental Medicine, Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126, Parma, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThe present study aimed to analyze the behaviors of three intraoral scanners (IOSs): evaluating the interdistance and axial inclination discrepancies in full-arch scans, predictable errors were searched. MATERIALS AND

methodsSix edentulous sample models with variable numbers of dental implants were used; reference data were obtained with a coordinate-measuring machine (CMM). Each IOS (i.e., Primescan, CS3600, and Trios3) performed 10 scans per model (180 total scans). The origin of each scan body was used as a reference point to measure interdistance lengths and axial inclinations. Precision and trueness of interdistance measurements and axial inclinations were evaluated to address error predictability. Bland-Altman analysis, followed by linear regression analysis and Friedman's test (plus Dunn's post hoc correction), was performed to evaluate the precision and trueness.

resultsRegarding interdistance, Primescan showed the best precision (mean ± SD: 0.047 ± 0.020 mm), while Trios3 underestimated the reference value more than the others (p < 0.001) and had the worst performance (mean ± SD: -0.079 ± 0.048 mm). Concerning the inclination angle, Primescan and Trios3 tended to overestimate angle values, while CS3600 underestimated them. Primescan had fewer inclination angle outliers, but it tended to add 0.4-0.6° to the measurements.

conclusionsIOSs showed predictable errors: they tended to overestimate or underestimate linear measurements and axial inclinations of scan bodies, one added 0.4-0.6° to the angle inclination values. In particular, they showed heteroscedasticity, a behavior probably related to the software or the device itself. CLINICAL SIGNIFICANCE: IOSs showed predictable errors that could affect clinical success. When performing a scan or choosing a scanner, clinicians should clearly know their behaviors.

Indexed as

Dental ImplantsImaging, Three-DimensionalComputer-Aided DesignDental Impression TechniqueModels, DentalDental ImplantsAccuracyDigital dentistryFull-arch scanImplant scan bodyImplant-supported prosthesis

Identifiers

PMID37041271
PMCPMC10329595

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.