Evidence map›Paper›PMID 37038794›Full record

ArticleTechnology and health care : official journal of the European Society for Engineering and Medicine2023

Time-efficient implantable catheters for draining malignant ascites in terminal cancer patients.

Hyeonjong Kim, Soyeong Bae, Ye-Jin Kim, So-Young Jung, Jin-Han Park, Si-Hyung Park, Il-Hwan Kim, Junghyuk Ko

Open access · bronzeAbstract read
In one paragraph

Article in Technology and health care : official journal of the European Society for Engineering and Medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 48% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Hyeonjong KimDepartment of Mechanical Engineering, Korea Maritime and Ocean University, Busan, Korea.
Soyeong BaeDepartment of Mechanical Engineering, Korea Maritime and Ocean University, Busan, Korea.
Ye-Jin KimDepartment of Pediatrics, Haeundae Paik Hospital, College of Medicine, Inje University, Busan, Korea.
So-Young JungDepartment of Dermatology, Haeundae Paik Hospital, College of Medicine, Inje University, Busan, Korea.
Jin-Han ParkDepartment of Pulmonology, Haeundae Paik Hospital, Inje University, Busan, Korea.
Si-Hyung ParkDepartment of Nephrology, Haeundae Paik Hospital, Inje University, Busan, Korea.
Il-Hwan KimDepartment of Oncology, Haeundae Paik Hospital, College of Medicine, Inje University, Busan, Korea.
Junghyuk KoDepartment of Mechanical Engineering, Korea Maritime and Ocean University, Busan, Korea.
Inje University Haeundae Paik Hospital · KRKorea Maritime and Ocean University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThere is a need for an improved version of the implantable catheter for malignant ascites in the abdominal cavity.

objectiveNew implantable catheters have been developed that drain ascites from the abdominal cavity to the bladder by applying pressure. Based on pigtail catheters, these newly designed catheters have silicone membranes and apertures.

methodsExperimental instruments controlled flow rates and water level to observe changes of the activation pressure and its cycle time along flow rates and turns of catheters. Furthermore, various normality tests, difference tests and non-parametric tests were investigated to observe statistical validity.

resultsCycle times were significantly affected by flow rate (3/4 cases of p< 0.05). The effects of flow rate on activation pressure, however, were not significant (1/4 case of p< 0.05). Cycle times were not significantly affected by the number of turns of the catheter (3/8 cases of p< 0.05). In contrast, the effects of the turns on activation pressure were significant (5/8 cases of p< 0.05).

conclusionOverall, there was no significant difference between cycle times for 1.5 turns and 2.0 turns of catheters. In addition, catheters with 1.5 turns have a lower activation pressure than catheters with 2.0 turns. It is possible to customize catheters based on the ascites excretion and urination rates of various terminal patients.

Indexed as

AscitesNeoplasmsCatheters, IndwellingDrainageHumansUrinary BladderImplantable cathetermalignant ascitesterminal cancertime efficiency

Identifiers

PMID37038794
PMCPMC10200217
OpenAlexW4362696318

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC