ArticleNature biomedical engineering2023
A battery-less wireless implant for the continuous monitoring of vascular pressure, flow rate and temperature.
Article in Nature biomedical engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 71 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
71 citing papers in PubMed.
- A Geometrically Transient Platform for Bioelectronic Implants.Advanced materials (Deerfield Beach, Fla.) · 2026Article
- Continuous Molecular Monitoring Using Electrochemical Aptamer-Based Sensors: Remaining Challenges for Long-Term In Vivo Deployment.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Review
- Nanomaterial -enabled flexible sensors for continuous biomedical monitoring and closed-loop intervention.Discover nano · 2026Review
- Iontronic tip-sensing guidewires.Nature biomedical engineering · 2026Article
- In Vivo Continuous Biosensing: Design Considerations and Emerging Technologies.Small (Weinheim an der Bergstrasse, Germany) · 2026Review
- Chemical-Sensing Catheters for Long-Term and Personalized Therapeutic Management.Advanced materials (Deerfield Beach, Fla.) · 2026Article
- Real-time soft tissue balance assessment in total knee arthroplasty using a wireless flexible sensor array.Medical & biological engineering & computing · 2026Article
- Triboelectric Wearable Sensors for Human-Centric Smart Electronics: From Self-Powered Sensing to Artificial Intelligence-Assisted Human-Machine Interface Systems.Nano-micro letters · 2026Review
- Polymer-Based Flexible Wireless Sensors for Health Monitoring.Nano-micro letters · 2026Review
- A miniature magnetic switch unlocking multimodal, chip-free, and batteryless airway sensing.Science advances · 2026Article
- Transforming healthcare through in-body bioelectronic systems.Nature communications · 2026Review
- Low-frequency ionic-electronic coupling for energy-efficient noise-resilient wireless bioelectronics.Nature communications · 2026Article
- Hemodynamics-driven magnetoelastic vascular grafts for stenosis diagnosis.Nature biotechnology · 2026Article
- Mechanomedicine.Nature reviews bioengineering · 2026Article
- Laser Micromachining for Bioelectronics: Past, Present, and Future.Small methods · 2026Review
- A Wearable, Dual Closed-loop Insulin Delivery System for Precision Diabetes Management.Advanced materials (Deerfield Beach, Fla.) · 2026Article
- Synthetic X‑ray‑driven tracking and control of miniature medical devices.Nature machine intelligence · 2026Article
- A wireless implantable sensory ring for continuous airway stent migration tracking.Npj flexible electronics · 2026Article
- Advances in Surface Biofunctionalization and Intelligent Monitoring of Vascular Scaffolds.Research (Washington, D.C.) · 2026Review
- An Active, Multimodal Neural Interface for Real-Time Monitoring of Cortical Electrical, Thermal, and Optical Dynamics.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Article
11 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
20 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Devices for monitoring blood haemodynamics can guide the perioperative management of patients with cardiovascular disease. Current technologies for this purpose are constrained by wired connections to external electronics, and wireless alternatives are restricted to monitoring of either blood pressure or blood flow. Here we report the design aspects and performance parameters of an integrated wireless sensor capable of implantation in the heart or in a blood vessel for simultaneous measurements of pressure, flow rate and temperature in real time. The sensor is controlled via long-range communication through a subcutaneously implanted and wirelessly powered Bluetooth Low Energy system-on-a-chip. The device can be delivered via a minimally invasive transcatheter procedure or it can be mounted on a passive medical device such as a stent, as we show for the case of the pulmonary artery in a pig model and the aorta and left ventricle in a sheep model, where the device performs comparably to clinical tools for monitoring of blood flow and pressure. Battery-less and wireless devices such as these that integrate capabilities for flow, pressure and temperature sensing offer the potential for continuous monitoring of blood haemodynamics in patients.
Indexed as
Identifiers
37037964What OpenQuestion holds