Evidence map›Paper›PMID 37037222›Full record

ArticleThe Thoracic and cardiovascular surgeon2023

Minimized Hemodiafiltration for Extracorporeal Membrane Oxygenation in Infants.

Nicola Kwapil, Andreas Teske, Sven Dittrich, Robert Blumauer, Michela Cuomo, Ariawan Purbojo, Frank Münch

Open access · hybridAbstract read
In one paragraph

Article in The Thoracic and cardiovascular surgeon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 94% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Nicola KwapilDepartment of Pediatric Heart Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.ORCID 0000-0002-0862-3371
Andreas TeskeDepartment of Pediatric Heart Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.ORCID 0000-0001-8702-3800
Sven DittrichDepartment of Pediatric Cardiology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.ORCID 0000-0002-8455-3416
Robert BlumauerDepartment of Pediatric Heart Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Michela CuomoDepartment of Pediatric Heart Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.ORCID 0000-0002-4069-5594
Ariawan PurbojoDepartment of Pediatric Heart Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.ORCID 0000-0002-5242-2630
Frank MünchDepartment of Pediatric Heart Surgery, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.ORCID 0000-0002-2790-0418
Friedrich-Alexander-Universität Erlangen-Nürnberg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFluid overload is a serious complication in the treatment of infants with extracorporeal membrane oxygenation (ECMO). Volume overload leads to prolonged ECMO therapy if left untreated. The renal replacement therapy of choice in pediatric patients is peritoneal dialysis or conventional dialysis using a "large" hemofiltration machine via a Shaldon catheter or directly connected to the ECMO system. This study describes the implementation of a novel minimized hemodiafiltration (HDF) system in pediatric patients on ECMO.

methodsThis retrospective analysis included 13 infants up to 5 kg who underwent 15 veno-arterial (V-A) ECMO runs with HDF. A minimized HDF system is integrated into an existing ECMO system (18-mL priming volume), connected post-oxygenation to the venous line, before the ECMO pump. Two infusion pumps are attached to the inlet and outlet of the hemofilter to control the HDF system.In addition to retention values (creatine and urea) at six defined time points, flow rates, dialysis parameters, and volume withdrawal were examined, as well as the number of HDF system changes.

resultsWith a mean ECMO runtime of 156 hours, the HDF system was utilized for 131 hours. The mean blood flow through the hemofilter was 192 mL/min. The mean dialysate flow was 170 mL/h, with a mean volume deprivation of 39 mL/h. The HDF system was changed once in seven cases and twice in three cases.

conclusionThere were no complications with the minimized HDF system in all 15 applications. It allows safe patient volume management when treating infants with ECMO, with effective elimination of urinary substances.

Indexed as

Extracorporeal Membrane OxygenationHemodiafiltrationChildHumansInfantRenal DialysisRetrospective StudiesTreatment Outcome

Identifiers

PMID37037222
PMCPMC10118294
OpenAlexW4364303248

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.