ArticlePloS one2023
Evaluating the contact anatomy and contact bone volume of spinal screws using a novel drilled surface image.
Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Intraoperative navigation systems have been widely applied in spinal fusion surgery to improve the implantation accuracy of spinal screws using orthogonal tomographic and surface-rendering imaging. However, these images contain limited anatomical information and no information on bone volume contact by the implanted screw, which has been proven to affect the stability of implanted screws. This study proposed a novel drilled surface imaging technique that displays anatomical integration properties to calculate the contact bone volume (CBV) of the screws implanted along an implantation trajectory. A cylinder was used to represent the area traversed by the screws, which was manually rotated and translated to a predetermined implantation trajectory according to a vertebra model obtained using computed tomography (CT) image volumes. The drilled surface image was reconstructed by interpolating the CT numbers at the predefined sampling points on the cylinder surface. The anatomical integration property and CBV of the screw implanted along the transpedicular trajectory (TT) and cortical bone trajectory (CBT) were evaluated and compared. The drilled surface image fully revealed the contact anatomical structure of the screw under the trajectories, improving the understanding of the anatomical integration of the screw and surrounding tissues. On average, the CBV of the CBT was 30% greater than that of the TT. The proposed drilled surface image may be applied in preoperative planning and integrated into intraoperative navigation systems to evaluate the anatomical integration and degree of bone contact of the screw implanted along a trajectory.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.