Evidence map›Paper›PMID 37036033›Full record

ArticleMagnetic resonance in medicine2023

Concomitant magnetic-field compensation for 2D spiral-ring turbo spin-echo imaging at 0.55T and 1.5T.

Zhixing Wang, Rajiv Ramasawmy, Xue Feng, Adrienne E Campbell-Washburn, John P Mugler, Craig H Meyer

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Article
  9. An evolution of low-field strength MRI.Magma (New York, N.Y.) · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Zhixing WangDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.ORCID 0000-0002-8189-0601
Rajiv RamasawmyCardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.
Xue FengDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.ORCID 0000-0002-2181-9889
Adrienne E Campbell-WashburnCardiovascular Branch, Division of Intramural Research, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.ORCID 0000-0002-7169-5693
John P MuglerDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.
Craig H MeyerDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.

Funding

Development of high-performance low field MRI technology ZIAHL006257 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI CAMPBELL-WASHBURN, ADRIENNE · 2021 to 2025
$8.1M
Comprehensive MRI Guidance of Focused Ultrasound NeurosurgeryR01EB028773 · NIBIB · UNIVERSITY OF VIRGINIA · PI MEYER, CRAIG H · 2020 to 2023
$2.1M
Intramural NIH HHS ZIA HL006257NHLBI NIH HHS Z1A-HL006257NIBIB NIH HHS R01 EB028773
6 · The paper itself

Abstract

purposeTo develop 2D turbo spin-echo (TSE) imaging using annular spiral rings (abbreviated "SPRING-RIO TSE") with compensation of concomitant gradient fields and B

methodsStrategies of gradient waveform modifications were implemented in SPRING-RIO TSE for compensation of self-squared concomitant gradient terms at the TE and across echo spacings, along with reconstruction-based corrections to simultaneously compensate for the residual concomitant gradient and B

resultsSimulation showed how concomitant fields affected the signal evolution with no compensation, and both simulation and phantom studies demonstrated the performance of the proposed sequence modifications, as well as the readout off-resonance corrections. Volunteer data showed that after full correction, the SPRING-RIO TSE sequence achieved high image quality with improved SNR efficiency (15%-20% increase), and reduced RF SAR (˜50% reduction), compared to the standard Cartesian TSE, presenting potential benefits, especially in regaining SNR at low-field (0.55T).

conclusionImplementation of SPRING-RIO TSE with concomitant field compensation was tested at 0.55T and 1.5T. The compensation principles can be extended to correct for other trajectory types that are time-varying along the echo train and temporally asymmetric in TSE-based imaging.

Indexed as

BrainMagnetic Resonance ImagingHumansImage EnhancementMagnetic PhenomenaPhantoms, Imagingconcomitant gradient fieldfast imagingspiral imagingturbo spin-echo imaging

Identifiers

PMID37036033
PMCPMC10578525

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.