Evidence map›Paper›PMID 37035613›Full record

ArticleShoulder & elbow2023

Anatomic Monopolar Press-fit Radial Head Arthroplasty; High Rate of Loosening at Mid-Term Follow Up.

Inderpaul Samra, Tariq A Kwaees, Wael Mati, Clare Blundell, Suzanne Lane, John Wk Harrison, Charalambos P Charalambous

Abstract read
In one paragraph

Article in Shoulder & elbow, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Inderpaul SamraDepartment of Orthopaedics, Blackpool Victoria Hospital, Whinney Heys Road, Blackpool, Lancashire, FY3 8NR, UK.ORCID https://orcid.org/0000-0002-0250-9447
Tariq A KwaeesDepartment of Orthopaedics, Blackpool Victoria Hospital, Whinney Heys Road, Blackpool, Lancashire, FY3 8NR, UK.
Wael MatiDepartment of Radiology, Blackpool Victoria Hospital, Whinney Heys Road, Blackpool, Lancashire, FY3 8NR, UK.
Clare BlundellDepartment of Orthopaedics, Blackpool Victoria Hospital, Whinney Heys Road, Blackpool, Lancashire, FY3 8NR, UK.
Suzanne LaneDepartment of Orthopaedics, Blackpool Victoria Hospital, Whinney Heys Road, Blackpool, Lancashire, FY3 8NR, UK.
John Wk HarrisonGateshead Health NHS Foundation Trust, Queen Elizabeth Avenue, Gateshead, NE9 6SX, UK.
Charalambos P CharalambousDepartment of Orthopaedics, Blackpool Victoria Hospital, Whinney Heys Road, Blackpool, Lancashire, FY3 8NR, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: Radial head arthroplasty (RHA) is used for the management of unstable or unreconstructable injuries of the radial head. Our aim was to investigate clinical and radiographic outcomes in patients treated with the Acumed anatomic radial head press-fit system for trauma. Methods: Clinical and radiographic assessment of RHAs undertaken for trauma with minimum 2-year follow-up. Results: 16 consecutive patients, mean age 53 (21-82) and 66 month ± 27 (26-122) clinical follow-up were included. There were marked radiographic changes with 11/16 showing periprosthetic lucent lines and 13/16 showing subcollar osteolysis. Radiographic changes occurred early post-surgery. Stem loosening was associated with larger cantilever quotients (0.47 vs 0.38, p  =  0.004). Overall survivability was 81.2%, with 3 RHAs removed. Clinical outcomes for the retained RHAs were acceptable with mean flexion 134°, extension deficit of 10°, pronation of 82°, and supination of 73°. Mean VAS scores were 8.5 ±  14.4, QuickDASH 13.8 ±  18.9, Mayo Elbow Performance Scores were 91.5 ±  12.5 with no poor scores. Conclusion: Mid-term clinical functional outcomes following the Acumed anatomic RHA are acceptable in most cases. However, in view of the extensive periprosthetic lucencies and surgical removal due to loosening, patients should be cautioned when consented for implantation of the prosthesis, especially if a large collar is anticipated.

Indexed as

elbow instabilityradial head arthroplastyradial head fractures

Identifiers

PMID37035613
PMCPMC10078816

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.